Inspection: 2766038 - Carbon Graphite Group Inc.

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 2766038
Report ID: 0452110
Date Opened: 08/24/1988

Site Address:
Carbon Graphite Group Inc.
4400 Bells Lane
Louisville, KY 40201

Mailing Address:
P. O. Box 3727, Lousiville, KY 40201

Union Status: Union

SIC:2819

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/03/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/14/1988


Related Activity
Type Activity Nr Safety Health
Referral 900180142 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $360 $0 $0 $0 $0 $360
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100303 B01 10/21/1988 08/24/1988 $360 $360 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Serious 19100307 B 10/21/1988 08/24/1988 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 995563
Event: 08/24/1988
Employee suffers 2nd- and 3rd-degree burns in explosion

At approximately 1:21 p.m. on August 18, 1988, Employee #1, a packer, was examining, packing, and re-packing returned industrial containers containing calcium chloride or other substances. After inspecting four containers, Employee #1 began packing another order. While inspecting the fifth container, serial #6001, Employee #1 used the wrong explosion-proof light to check the container for moisture and other contaminants that would interfere with the newly entered product. Employee #1 lowered a light approved for Class 1, Division 1, Class 1 Groups C & D, and Class II Group G atmospheres into a Class 1, Division 1, Group A atmosphere (acetylene), causing an explosion. Employee #1 suffered second- and third-degree burns to his face and upper chest. He was hospitalized.

Keywords: BURN, WORK RULES, EXPLOSION, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2766038 Hospitalized injury Burn/Scald(Heat) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.