Powered by GoogleTranslate

Inspection Detail

Inspection: 2322543 - Maurice Casey Inc

Inspection Information - Office: Springfield Area Office

 

Inspection Nr: 2322543
Report ID: 0112600
Date Opened: 05/23/1985

Site Address:
Maurice Casey Inc
19 Dubois Rd
Westfield, MA 01085

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5143

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/23/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/28/1985


Related Activity
Type Activity Nr Safety Health
Referral 900731597 Yes

Investigation Summary

Investigation Nr: 14560130
Event: 05/23/1985
EMPLOYEE OVERCOME WHEN HE INHALED AMMONIA VAPORS

EMPLOYEE #1, WHO WAS WORKING IN A NON-REFRIGERATED SECTION OF A REFRIGERATED MILK AND ICE CREAM STORAGE FACILITY, WAS OVERCOME BY AMMONIA VAPORS. THE AMMONIA HAD ESCAPED FROM A FAULTY VALVE IN THE PLANT'S INTERIOR PIPING SYSTEM.

Keywords: RESPIRATORY, AMMONIA, INHALATION, VALVE, GAS LEAK, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2322543 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.