Powered by GoogleTranslate

Inspection Detail

Inspection: 1933399 - Bardes Plastics Inc

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 1933399
Report ID: 0523400
Date Opened: 10/10/1984

Site Address:
Bardes Plastics Inc
5225 West Clinton Avenue
Milwaukee, WI 53223

Mailing Address:
Po Box 23567, Milwaukee, WI 53223

Union Status: NonUnion

SIC:3089

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/28/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/23/1985


Related Activity
Type Activity Nr Safety Health
Referral 900665795 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 12 12
Current Violations 12 12
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100022 D01 12/21/1984 01/21/1985 $0 $0 $0 -  
2. 01002 Other 19100023 C01 12/21/1984 02/21/1985 $0 $0 $0 -  
3. 01003 Other 19100132 A 12/21/1984 12/24/1984 $0 $0 $0 -  
4. 01004 Other 19100212 A01 12/21/1984 04/21/1985 $0 $0 $0 P - Petition to Mod Abatement  
5. 01005 Other 19100212 A03 II 12/21/1984 12/24/1984 $0 $0 $0 -  
6. 01006 Other 19100212 A05 12/21/1984 12/24/1984 $0 $0 $0 -  
7. 01007 Other 19100213 P04 12/21/1984 12/24/1984 $0 $0 $0 -  
8. 01008 Other 19100215 A02 12/21/1984 12/24/1984 $0 $0 $0 -  
9. 01009 Other 19100219 C02 I 12/21/1984 12/24/1984 $0 $0 $0 -  
10. 01010 Other 19100219 D01 12/21/1984 12/24/1984 $0 $0 $0 -  
11. 01011 Other 19100304 A02 12/21/1984 12/24/1984 $0 $0 $0 -  
12. 01012 Other 19100304 F05 V 12/21/1984 12/24/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 570804
Event: 10/04/1984
HAND AMPUTATED BY PLASTIC TRIM DIE

EMPLOYEE #1 WAS SETTING UP THE TRIM DIE FUNCTION OF A THERMOFORMER AS USED IN PLASTIC PART MANUFACTURE. AS HE WAS FINALIZING THE PROCEDURE, PRIOR TO THE PRODUCTION RUN, HE PLACED HIS RIGHT HAND IN THE DIE AREA. THE PLATEN DESCENDED (A VERTICAL STROKE OF 4 1/4") SEVERING HIS HAND BELOW THE WRIST, BETWEEN THE KNUCKLES AND SECOND JOINTS. THE INTERLOCKED SAFETY BARRIER GUARDS WERE LOWERED FOR THE SET-UP OPERATION. SAFETY BLOCKS, THOUGH PROVIDED, WERE NOT USED.

Keywords: SAFETY BLOCK, DIE, AMPUTATED, BARRIER GUARD, GUARD, POINT OF OPERATION, THERMOFORMER, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1933399 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close