Powered by GoogleTranslate

Inspection Detail

Inspection: 1929298 - The Cunard Lang Concrete Co

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 1929298
Report ID: 0522500
Date Opened: 11/01/1984

Site Address:
The Cunard Lang Concrete Co
498 Furnace St
Columbus, OH 43215

Mailing Address:
, , 00000

Union Status: Union

SIC:3271

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/06/1984

Emphasis:

Case Closed: 03/05/1985


Related Activity
Type Activity Nr Safety Health
Accident 360646079

Investigation Summary

Investigation Nr: 570531
Event: 10/31/1984
PRESSURE VESSEL USED FOR LUBRICATING MACHINERY BLEW APART

EMPLOYEE #1 WAS IN THE PROCESS OF LUBRICATING SOME MACHINERY WITH A PRESSURE VESSEL FILLED WITH LUBRICATING FLUID. THE PRESSURE VESSEL WAS ALLOWED TO BE FILLED TO AN EXCESSIVE PRESSURE, CAUSING IT TO BLOW APART. THE EMPLOYEE WAS STRUCK BY THE VESSEL, CAUSING MULTIPLE FRACTURES AND LACERATIONS. THE PRESSURE VESSEL WAS NOT CONSTRUCTED IN ACCORDANCE WITH ASME STANDARDS, AND DID NOT HAVE A SAFETY RELIEF VALVE.

Keywords: FRACTURE, SAFETY RELIEF VALVE, PRESSURE VESSEL, EXPLOSION, LACERATION, LUBRICATING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1929298 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.