Powered by GoogleTranslate

Inspection Detail

Inspection: 18513390 - Turner - Baxter Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 18513390
Report ID: 0453710
Date Opened: 05/30/1989

Site Address:
Turner - Baxter Inc.
247 Spring St. Nw
Concord, NC 28025

Mailing Address:
P. O. Box 288, Concord, NC 28025

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/01/1989

Emphasis:

Case Closed: 07/27/1989


Related Activity
Type Activity Nr Safety Health
Accident 360263370
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $550 $0 $0 $0 $0 $550
Current Penalty $550 $0 $0 $0 $0 $550
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 06/22/1989 06/28/1989 $350 $350 $0 -  
2. 01001B Serious 19260550 A15 I 06/22/1989 06/28/1989 $0 $0 $0 -  
3. 01002 Serious 19260556 B02 V 06/22/1989 06/28/1989 $200 $200 $0 -  
4. 02001 Other 19101200 E01 I 06/22/1989 07/25/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 942532
Event: 05/27/1989
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE

TWO EMPLOYEES WERE WORKING FROM AN EXTENSIBLE-BOOM AERIAL LIFT, REMOVING PAINT FROM THE SIDE OF A BUILDING. THEY WERE USING A PRESSURE WASHER AND AN ALUMINUM-HANDLED SCRUB BRUSH TO PERFORM THIS TASK. THE EMPLOYEES WERE WORKING NEAR A 4160-VOLT OVERHEAD POWER LINE. ONE OF THE EMPLOYEES HAD FINISHED SCRUBBING THE BUILDING SURFACE AND STEPPED BACK, AS THE SECOND EMPLOYEE RINSED THE BUILDING WITH THE PRESSURE WASHER. WHEN THE SECOND EMPLOYEE TURNED AROUND, HE NOTICED THAT THE FIRST EMPLOYEE WAS SITTING IN THE CORNER OF THE PLATFORM VOMITING. HE WAS TAKEN TO A HOSPITAL WHERE HE WAS PRONOUNCED DEAD OF ELECTROCUTION. THE SECOND EMPLOYEE WAS ALSO INJURED, BUT THE REPORT DID NOT STATE HOW THIS OCCURRED.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, UNTRAINED, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18513390 Fatality Electric Shock Painters, construction and maintenance
2 18513390 Non Hospitalized injury Electric Shock Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.