Powered by GoogleTranslate

Inspection Detail

Inspection: 1817642 - Faco Metal Products Inc

Inspection Information - Office: Providence Area Office

 

Inspection Nr: 1817642
Report ID: 0112300
Date Opened: 08/08/1984

Site Address:
Faco Metal Products Inc
248 Toronto Ave
Providence, RI 02905

Mailing Address:
3 Brayton Ave, Providence, RI 02903

Union Status: NonUnion

SIC:3873

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/14/1984

Emphasis:

Case Closed: 10/01/1984


Related Activity
Type Activity Nr Safety Health
Complaint 70688940 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 5 6
Current Violations 1 5 6
Initial Penalty $120 $0 $0 $0 $0 $120
Current Penalty $120 $0 $0 $0 $0 $120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100217 B03 II 08/25/1984 09/25/1984 $120 $120 $0 -  
2. 02001 Other 19030002 A01 08/25/1984 08/28/1984 $0 $0 $0 -  
3. 02002 Other 19100217 E01 I 08/25/1984 09/25/1984 $0 $0 $0 -  
4. 02003 Other 19100217 G 08/25/1984 08/28/1984 $0 $0 $0 -  
5. 02004 Other 19100219 B01 08/25/1984 08/28/1984 $0 $0 $0 -  
6. 02005 Other 19100219 D01 08/25/1984 08/28/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14277115
Event: 07/26/1984
FINGERS AMPUTATED IN A MECHANICAL POWER PRESS

ON JUNE 27,1984 EMPLOYEE #1 WAS OPERATING A ROUSELLE, 10 TON CAPACITY, FULL REVOLUTION, MECHANICAL POWER PRESS, ASSEMBLING 2 5/8" PENDULUM PIECES. THE PRESS REPEATED, RESULTING IN EMPLOYEE #1 LOSING PORTIONS OF TWO FINGERS. INVESTIGATION REVEALED THAT A TENSION TYPE COIL SPRING, SUSPENDING THE CLUTCH ENGAGEMENT LEVER, BROKE, ALLOWING THE LEVER TO DROP. THIS CAUSED THE PRESS TO COMPLETE A CYCLE AS IF IN AUTOMATIC MODE. THE PRESS WAS EQUIPPED WITH A TWO HAND CONTROL SYSTEM. THE SYSTEM'S ARRANGEMENT, INSTALLATION AND OPERATION SEEMED TO BE ADEQUATE AND WHEN TESTED DID FUNCTION AS REQUIRED.

Keywords: AMPUTATED, CLUTCH LEVER, POWER PRESS, FINGER, TWO-HAND CONTROL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1817642 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close