Powered by GoogleTranslate

Inspection Detail

Inspection: 17976705 - H And M Systems, Inc.

Inspection Information - Office: Puerto Rico Area Office

 

Inspection Nr: 17976705
Report ID: 0215300
Date Opened: 02/04/1987

Site Address:
H And M Systems, Inc.
13f Lindburg Bay St.
St. Thomas, VI 00802

Mailing Address:
P.O. Box 4671, Veterans Dr. Station, St. Thomas, VI 00802

Union Status: NonUnion

SIC:4959

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/12/1987

Emphasis:

Case Closed: 04/30/1987


Related Activity
Type Activity Nr Safety Health
Accident 360526560
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 1 2
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $480 $0 $0 $0 $0 $480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 A 03/09/1987 04/09/1987 $480 $480 $0 -  
2. 01001B Serious 19100132 A 03/09/1987 04/09/1987 $0 $0 $0 -  
3. 01001C Serious 19100134 A02 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
4. 01001D Serious 19100134 A02 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
5. 01001E Serious 19100134 A02 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
6. 01001F Serious 19100134 E01 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
7. 01001G Serious 19100134 E03 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
8. 01001H Serious 19100134 E03 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
9. 01001I Serious 19100134 E05 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
10. 02001 Other 19100134 F01 03/09/1987 04/30/1987 $0 $0 $0 A - Amendment  
11. 02002 Other 19101200 E01 03/09/1987 04/09/1987 $0 $0 $0 A - Amendment Citation has been deleted.
12. 02003 Other 19101200 G01 03/09/1987 04/09/1987 $0 $0 $0 A - Amendment Citation has been deleted.
13. 02004 Other 19101200 H01 03/09/1987 04/09/1987 $0 $0 $0 A - Amendment Citation has been deleted.

Investigation Summary

Investigation Nr: 14533129
Event: 02/02/1987
Employee dies of asphyxia after being overcome by gas

Employee #1 was repairing a sewage pump inside a 900 gallon cylindrical septic tank that was 6 ft high, 5 1/2 ft diameter at the top, and 4 3/5 ft diameter at the bottom. According to the medical examiner, Employee #1 was overcome by a gas, possibly methane. The autopsy report stated that Employee #1 died of asphyxia, which was secondary to methane inhalation. No methane was measured or detected by the medical examiner. Employee #1 was not issued the proper respirator. Employees had not been trained.

Keywords: ASPHYXIATED, REPAIR, VENTILATION, CONFINED SPACE, WORK RULES, INHALATION, NATURAL GAS, TANK, UNTRAINED, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 17976705 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close