Powered by GoogleTranslate

Inspection Detail

Inspection: 17710294 - Allstate Power Vac, Inc.

Inspection Information - Office: Osha Philadelphia Area Office

 

Inspection Nr: 17710294
Report ID: 0317000
Date Opened: 03/22/1994

Site Address:
Allstate Power Vac, Inc.
Delaware And Green Sts.
Marcus Hook, PA 19061

Mailing Address:
2527 Market Street, Twin Oaks, PA 19014

Union Status: Union

SIC:2911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/27/1994

Emphasis: N:Psmpqv

Case Closed: 06/10/1994


Related Activity
Type Activity Nr Safety Health
Accident 360468060

Investigation Summary

Investigation Nr: 14316491
Event: 03/21/1994
Employees injured by sludge when tank explodes

Employees were performing hot work on a tank. The tank blew off the foundation, releasing a tidal wave of sludge. Employees #1 through #18 were injured when they ingested the sludge and were swept away by it.

Keywords: EXPLOSION, TANK, CONSTRUCTION, WELDING, SLUDGE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 17710294 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close