Powered by GoogleTranslate

Inspection Detail

Inspection: 17374885 - Camac Corporation

Inspection Information - Office: Va-E-Abingdon (Field Office) - Safety 0355110

 

Inspection Nr: 17374885
Report ID: 0355110
Date Opened: 05/23/1987

Site Address:
Camac Corporation
Washington County Industrial Park
Bristol, VA 24201

Mailing Address:
P. O. Box 1004, Bristol, VA 24201

Union Status: NonUnion

SIC:2241

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/29/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/27/1987


Related Activity
Type Activity Nr Safety Health
Accident 360789176

Investigation Summary

Investigation Nr: 14225163
Event: 05/22/1987
EMPLOYEES INHALED SMOKE FROM PETROLEUM ETHER FIRE

EMPLOYEE #6 WAS PERFORMING FINISH EXTRACTIONS ON YARN. THIS OPERATION CONSISTS OF DIPPING THE YARN INTO A WARM SOLUTION OF PETROLEUM ETHER, THEN EVAPORATING THE ETHER FROM THE YARN. A CORNING PC-100RC SERIES LABORATORY HOT PLATE WAS USED. AT APPROXIMATELY 7 PM ON MAY 22, 1987, EMPLOYEE #6 WAS EVAPORATING THE SECOND SET OF FOUR SIMULTANEOUS EXTRACTIONS, AND WAS STANDING NEAR THE SINK BESIDE THE FUME HOOD. THE HOOD FAN AND FUME HOOD LIGHTS WERE ON. THE FUME HOOD DOOR WAS PULLED DOWN ABOUT HALFWAY. THERE APPEARS TO HAVE BEEN A POP, AND THE MATERIAL INSIDE THE FUME HOOD CAUGHT FIRE. EMPLOYEE #6 AND EMPLOYEE #3 LEFT THE LABORATORY IMMEDIATELY AND INFORMED EMPLOYEE #8 OF THE FIRE. EMPLOYEE #3 PAGED EMPLOYEE #5 TO COME TO THE LABORATORY IMMEDIATELY TO DEAL WITH THE EMERGENCY. MEANWHILE, EMPLOYEE #8 FOUND A FIRE EXTINGUISHER. EMPLOYEE #4 TOOK THE FIRE EXTINGUISHER FROM EMPLOYEE #8 AND EXTINGUISHED THE FUME HOOD FIRE. THE FIRE MELTED THE PLEXIGLASS OF THE FUME HOOD, AND THE FAN MOTOR WOULD NOT OPERATE AFTER THE FIRE. THE LAMP IN THE FUME HOOD WAS BROKEN. THERE WAS A BEAKER CONTAINING APPROXMATELY 50 MILLILITERS OF UNBURNED PETROLUEM ETHER SITTING BESIDE THE HOT PLATE. THE HEAT APPARENTLY CAUSED THE PLEXIGLASS DOOR TO BULGE OUTWARD IN THE AREA ABOVE THE HOT PLATE. THE PROTECTIVE COVER FOR THE LAMP INSIDE THE FUME HOOD WAS MISSING. ALL 8 EMPLOYEES WERE HOSPITALIZED FOR SMOKE INHALATION.

Keywords: RESPIRATORY, FLAMMABLE VAPORS, FIRE, SMOKE, SMOKE INHALATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 17374885 Hospitalized injury Asphyxia Winding and twisting machine operators
2 17374885 Hospitalized injury Asphyxia Winding and twisting machine operators
3 17374885 Hospitalized injury Asphyxia Management related occupations, n.e.c.
4 17374885 Hospitalized injury Asphyxia Management related occupations, n.e.c.
5 17374885 Hospitalized injury Asphyxia Management related occupations, n.e.c.
6 17374885 Hospitalized injury Asphyxia Management related occupations, n.e.c.
7 17374885 Hospitalized injury Asphyxia Occupation not reported
8 17374885 Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.