Powered by GoogleTranslate

Inspection Detail

Inspection: 1662097 - Globe Metallurgical Inc

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 1662097
Report ID: 0522500
Date Opened: 02/05/1985

Site Address:
Globe Metallurgical Inc
Count Road 32
Waterford, OH 45786

Mailing Address:
P O Box 157, Beverly, OH 45715

Union Status: Union

SIC:3313

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/14/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/28/1985


Related Activity
Type Activity Nr Safety Health
Accident 360541338
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $1,800 $0 $0 $0 $0 $1,800
Current Penalty $400 $0 $0 $0 $0 $400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 04/17/1985 04/20/1985 $900 $900 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19100132 A 04/17/1985 04/20/1985 $400 $900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 570614
Event: 02/03/1985
TRAP GAS ERUPTION

THE EMPLOYEES WERE IN THE PROCESS OF SLIPPING AN ELECTRODE AND HAD TO LOOSEN TWO BOLTS THAT ATTACHED THE HOLDING RING AND SHOES TO THE ELECTRODE. THEY LOOSENED ONE BOLT AND WERE IN THE PROCESS OF LOOSENING THE SECOND BOLT. THE ELECTRODE SLIPPED DOWN, RELEASING A POCKET OF TRAP GASES. BEFORE BEGINNING THIS PROCESS, THE FURNACE OPERATOR WILL NORMALLY STOKE UP THE MIX. THIS IS AFTER THE TAPER OPERATOR HAD DRAINED OUT MOST OF THE MOLTEN FE CA SILICIDE. HE WILL THEN ADD DRY MIX TO THE FURNANCE, STOKE THE DRY MIX AND COVER THE ENTIRE FURNACE BEFORE TRYING TO SLIP THE ELECTRODE.

Keywords: FURNACE, TRAP GAS, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1662097 Fatality Burn/Scald(Heat) Occupation not reported
2 1662097 Fatality Burn/Scald(Heat) Occupation not reported
3 1662097 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close