Powered by GoogleTranslate

Inspection Detail

Inspection: 1532217 - Tacoma Boat Building Co Inc

Inspection Information - Office: Washington Area Office

 

Inspection Nr: 1532217
Report ID: 1032300
Date Opened: 09/06/1984

Site Address:
Tacoma Boat Building Co Inc
1840 Marine View Dr
Tacoma, WA 98422

Mailing Address:
, , 00000

Union Status: Union

SIC:3731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/07/1984

Planning Guide: Safety-Maritime

Emphasis: L:Ship

Case Closed: 10/03/1984


Related Activity
Type Activity Nr Safety Health
Accident 360635130
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $630 $0 $0 $0 $0 $630
Current Penalty $630 $0 $0 $0 $0 $630
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 D03 09/18/1984 09/21/1984 $630 $630 $0 -  
2. 02001 Other 19150055 E01 09/18/1984 09/21/1984 $0 $0 $0 -  
3. 02002 Other 19150131 G 09/18/1984 09/21/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14509525
Event: 09/05/1984
EMPLOYEE ASPHYXIATED AFTER BREATHING ARGON GAS FROM AIRLINE

EMPLOYEE #1 WAS A PAINTER WHO WORKED ON THE SWING SHIFT. HE WAS ASSIGNED THE JOB OF PAINTING THE INSIDE OF A POTABLE WATER TANK, LOCATED ON THE STARBOARD SIDE OF THE AUXILIARY ENGINE SPACE ON THE VESSEL "AOLLO ONE". HE CLEANED SOME WATER OUT OF THE TANK, THEN HOOKED A HOSE TO AN AIR MANIFOLD ABOARD THE VESSEL. HE HOOKED THE OTHER END OF THE HOSE TO A BOARD ON WHICH WAS MOUNTED AN AIR FILTER AND OUTLETS FOR HIS SPRAY PAINT GUN. HE ATTACHED A NORTON FULL FACE AIR LINE RESPIRATOR TO THE FILTER, PUT IT ON AND QUICKLY PASSED OUT. HE WAS FOUND BY HIS LEADMAN BETWEEN 90 AND 150 MINUTES LATER. INVESTIGATION SHOWED THAT THE AIR MANIFOLD HAD BEEN ATTACHED TO AN ARGON GAS OUTLET ON THE PIER. THE ARGON OUTLET HAD BEEN FITTED WITH AN AIR TYPE FITTING.

Keywords: AIR LINE RESPIRATOR, ASPHYXIATED, PAINTER, ARGON, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1532217 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close