Inspection Detail
Inspection: 1501977.015 - Sterling Bridge, Llc
Inspection Information - Office: Naperville Area Office
Site Address: 
			   Sterling Bridge, Llc
			   1241 N. Ellis
Bensenville, IL 60106
Mailing Address: 
			   1241 N. Ellis, Bensenville, IL 60106
Union Status: NonUnion
SIC:
NAICS: 333249
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/10/2021
Emphasis: N:Dustexpl
Case Closed: 10/01/2023
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 1686013 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 1 | 7 | |||
| Current Violations | 3 | 1 | 4 | |||
| Initial Penalty | $54,612 | $0 | $0 | $1,366 | $0 | $55,978 | 
| Current Penalty | $40,959 | $0 | $0 | $0 | $0 | $40,959 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19100134 F02 | 05/10/2021 | 06/16/2021 | $0 | $8,192 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 3. | 01003 | Serious | 19100134 K01 | 05/10/2021 | 06/16/2021 | $0 | $8,192 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 4. | 01004 | Serious | 19100307 C | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
| 5. | 01005A | Serious | 19101200 G02 II | 05/10/2021 | 02/17/2023 | $13,653 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | |
| 6. | 01005B | Serious | 19101200 G02 III | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 7. | 01006A | Serious | 19101200 H01 | 05/10/2021 | 06/16/2021 | $0 | $9,557 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 8. | 01006B | Serious | 19101200 H02 II | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 9. | 01006C | Serious | 19101200 H03 I | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 10. | 01006D | Serious | 19101200 H03 II | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 11. | 01006E | Serious | 19101200 H03 III | 05/10/2021 | 06/16/2021 | $0 | $0 | $0 | 05/12/2021 | F - Formal Settlement | Citation has been deleted. | 
| 12. | 02001 | Other | 19040040 A | 05/10/2021 | 06/16/2021 | $0 | $1,366 | $0 | 05/12/2021 | F - Formal Settlement | 
Investigation Summary
At 4:30 p.m. on November 11, 2020, two employees were in the process of producing batches of a chlorine dioxide generator inside a newly purchased mixer. Employee #1 was killed in an explosion after closing the lid on the mixer to complete the mixing operations. Employee #2 was injured during the rescue attempt. The manufacturing room and the surrounding area sustained extensive damage.
Keywords: Chlorine Dioxide, Electric Generator, Explosion, Fire, Mixer
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 1501977.015 | 27 | M | Fatality | ||
| 2 | 1501977.015 | 0 | M | Hospitalized injury | 