Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1501662.015 - R H Plumbing, Inc.

Inspection Information - Office: Jackson

Nr: 1501662.015Report ID: 0419400Open Date: 11/04/2020

R H Plumbing, Inc.
1804 S. Green St.Null
Tupelo, MS 38801
Union Status: NonUnion
SIC:
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Mailing: P.O. Box 417null, Okolona, MS 38860

Inspection Type:Fat/Cat
Scope:Complete Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:11/06/2020
Close Case:

Related Activity:TypeIDSafetyHealth
 Accident1683239    
 Inspection1502111 Yes  
 Inspection1501723 Yes  

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $28,398 $0 $0 $0 $0 $28,398
Current Penalty $28,398 $0 $0 $0 $0 $28,398
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19100147 C04 I 04/30/2021 05/24/2021 $13,653 $13,653 $0 Z - Issued
  2. 01002 Serious 19100147 C07 I A 04/30/2021 05/24/2021 $6,144 $6,144 $0 Z - Issued
  3. 01003A Serious 19100147 D03 04/30/2021 05/24/2021 $8,601 $8,601 $0 Z - Issued
  4. 01003B Serious 19100147 D04 I 04/30/2021 05/24/2021 $0 $0 $0 Z - Issued
  5. 01003C Serious 19100147 D06 04/30/2021 05/24/2021 $0 $0 $0 Z - Issued
  6. 02001 Other 19100147 F02 I 04/30/2021 05/24/2021 $0 $0 $0 Z - Issued

Accident Investigation Summary
Summary Nr: 130981.015Event: 11/03/2020Employee Is Struck And Killed In Air Pressure Release Incide
At 1:15 p.m. on November 3, 2020, Employee #1, employed by an HVAC company, was working at a customer's commercial facility. He was in the process of removing a coupler and blind from the intake header of an air dryer. The employee did no t first relieve the air pressure from the header. When he loosened the coupler bolts, the coupler and blind were propelled off the header by the pressure relea se. Employee #1 was struck by the flying parts. Employee #1 sustained blunt fo rce traumatic injuries and was killed.
Keywords: air pressure, blunt force trauma, bolt, couplings, dismantling, hvac, high pressure, maintenance, plumbing, pressure release, repair, struck by
Inspection Degree Nature Occupation
1 1501662.015 Fatality Plumbers, pipefitters and steamfitters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close