Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: OPEN

Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1497090.015 - Jose Santamaria Lopez Dba Jl And Son

Inspection Information - Office: Madison

Nr: 1497090.015Report ID: 0523300Open Date: 10/13/2020

Jose Santamaria Lopez Dba Jl And Son
1497 Spring Roadnull
Stoughton, WI 53589
Union Status: NonUnion
SIC:
NAICS: 238170/Siding Contractors
Mailing: 1520 Ravine Streetnull, Janesville, WI 53548

Inspection Type:Fat/Cat
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:10/13/2020
Close Case:

Related Activity:TypeIDSafetyHealth
 Accident1671824    
Case Status: OPEN

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $19,278 $0 $0 $0 $0 $19,278
Current Penalty $19,278 $0 $0 $0 $0 $19,278
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 19260020 B01 12/18/2020 01/05/2021 $2,892 $2,892 $0 Z - Issued
  2. 01002A Serious 19260021 B02 12/18/2020 01/05/2021 $2,892 $2,892 $0 Z - Issued
  3. 01002B Serious 19260451 F07 12/18/2020 01/05/2021 $0 $0 $0 Z - Issued
  4. 01003 Serious 19260451 F06 12/18/2020 01/05/2021 $13,494 $13,494 $0 Z - Issued

Accident Investigation Summary
Summary Nr: 130277.015Event: 10/13/2020One Is Electrocuted, One Is Injured When Pole Contacts Power
At 9:30 a.m. on October 13, 2020, Employees #1 and #2, employed by a siding comp any, were erecting a pump jack scaffold at a single-family residence in preparat ion for installation work. The outdoor winds exceeded 17 miles per hour with ev en stronger gusts. As they erected a 24-foot scaffold pole support adjacent to the house, the pole made contact with a live and uninsulated 7,200-volt primary power line that ran parallel to the house. The power line was approximately 23 feet 8 inches above the ground and approximately 12 feet away from the house. E mployee #1 was electrocuted. Employee #2 sustained electric shock injuries that required hospitalization and treatment.
Keywords: contact, electric shock, electrocuted, energized, erection process, installing, metal pole, overhead power line, power lines, pump jack scaffold, residential construction, windy
Inspection Degree Nature Occupation
1 1497090.015 Fatality Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.