Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: VIOLATIONS UNDER CONTEST

Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1471037.015 - North Houston Pole Line, Lp

Inspection Information - Office: Houston South

Nr: 1471037.015Report ID: 0626700Open Date: 03/25/2020

North Houston Pole Line, Lp
12525 East I-10 Frontage
Baytown, TX 77523
Union Status: NonUnion
SIC:
NAICS: 237130/Power and Communication Line and Related Structures Construction
Mailing: 1608 Margaret St., Houston, TX 77093

Inspection Type:Fat/Cat
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/25/2020
Close Case:

Related Activity:TypeIDSafetyHealth
 Accident1558534    
Case Status: VIOLATIONS UNDER CONTEST

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $13,494 $0 $0 $0 $0 $13,494
Current Penalty $13,494 $0 $0 $0 $0 $13,494
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Serious 5A0001 09/03/2020 09/23/2020 $13,494 $13,494 $0 10/02/2020 -

Accident Investigation Summary
Summary Nr: 125016.015Event: 03/24/2020Employee Is Killed When Struck By Pipe Tongs While Boring
At 9:00 a.m. on March 24, 2020, Employee #1 and some Coworkers, boring operators (crew), were running wire inside of drill stems, while installing a power transmission line and as his coworkers stopped to clean the mud pit, Employee #1 then placed a pipe tong on a stem. After the mud pit was cleaned, Coworker #1, a foreman, instructed the boring operator to initiate boring; however, the area surrounding the pipe stems was not cleared and as result, Employee #1 was struck in the back of the head by the pipe tong attached to the stem. Afterwards, Employee #1 sustained blunt force trauma to the head and was then transported to the hospital and later pronounced dead.
Keywords: wire line, electrical, installing, inattention, head, electrical work, elec utility work, elec insulation, elec equipment--misc, drill, blunt force trauma, operator, cleaning, conduit, contact, blunt force
Inspection Degree Nature Occupation
1 1471037.015 Fatality Other Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.