Inspection Detail
Inspection: 14627616 - Kammann Development
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Kammann Development
1342 23rd Drive
Yuma, AZ 85364
Mailing Address:
755 W 28th Street, Yuma, AZ 85364
Union Status: NonUnion
SIC:1521
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/02/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/03/2016
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360578520 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $210 | $0 | $0 | $0 | $0 | $210 |
Current Penalty | $210 | $0 | $0 | $0 | $0 | $210 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260401 A01 | 08/10/1984 | 08/13/1984 | $210 | $210 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS INSTALLING KITCHEN CABINETS IN A HOUSE THAT WAS UNDER CONSTRUCTION. ABOUT 200 FEET OF NONMETALLIC SHEATHED CABLE WAS WIRED TO A CIRCUIT BREAKER PANELBOARD FOR A HOUSE ACROSS THE STREET. THE CABLE RAN TO THE BACK YARD OF THE HOUSE UNDER CONSTRUCTION, WHERE A 100-FOOT, 3-CONDUCTOR EXTENSION CORD SET WAS PLUGGED INTO AN OUTLET BOX INSTALLED ON THE CABLE. THE ATTACHMENT PLUG ON THE EXTENSION CORD HAD BEEN REPLACED WITH A TWO-PRONG, NON-GROUNDING-TYPE PLUG. A 3/8-INCH DRILL ADAPTED FOR USE AS AN ELECTRIC SCREW DRIVER HAD A 3-CONDUCTOR POWER CORD WITH THE GROUNDING PRONG MISSING FROM ITS ATTACHMENT PLUG. THE ELECTRIC SCREW DRIVER WAS PLUGGED INTO THE EXTENSION CORD. TO PERFORM HIS JOB, THE EMPLOYEE WAS SITTING ON THE FLOOR, UNDERNEATH THE KITCHEN SINK, LEANING AGAINST A COPPER WATER PIPE. WHILE HE WAS HOLDING THE ELECTRIC SCREW DRIVER IN THIS POSITION, A GROUND FAULT OCCURRED WITHIN THE DRILL MOTOR ENERGIZING THE METAL CASE. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: ELECTRICAL, ATTACHMENT PLUG, E C, GROUND FAULT, EQUIPMENT GROUNDING, TEMPORARY WIRING, CORD SET, ELECTROCUTED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 14627616 | Fatality | Electric Shock | Cabinet makers and bench carpenters |