Inspection: 1438175 - Brandt Engineering Inc

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 1438175
Report ID: 0626300
Date Opened: 04/27/1984

Site Address:
Brandt Engineering Inc
900 Jackson St
Dallas, TX 75202

Mailing Address:
Po Box 29559, Dallas, TX 75229

Union Status: NonUnion

SIC:1711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/14/1984

Emphasis:

Case Closed: 03/19/1985


Related Activity
Type Activity Nr Safety Health
Accident 360551865
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $700 $0 $0 $0 $0 $700
Current Penalty $350 $0 $0 $0 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100105 05/29/1984 06/01/1984 $350 $700 $0 J - ALJ Decision  

Investigation Summary

Investigation Nr: 14465413
Event: 04/27/1984
Employee killed in 100 ft fall through duct openings

Employee #1 and coworkers were working in a seven-story building that was being renovated. They were installing a 2 ft by 4 ft metal air duct up through 8 ft by 16 ft in-line floor openings that had not been walled in. The duct sections were raised up for installation using a chain hoist fixed to a 4 by 4 wooden beam laid across the opening in a floor above. Two 2 in. by 10 in. wood planks were laid across the 8 ft wide span. The workers walked out on these planks to secure the hoisted duct. Upon completion, the hoist was removed from the 8 ft by 16 ft roof opening where it was last fixed. Employee #1 was killed when he lost his balance and fell approximately 100 ft to the basement. No safety belts or safety lines were in use or made available. The floor openings beside the duct had not been covered on any of the floors below, except for the two 2 in. by 10 in. planks; these only covered 20 in. of the 4 to 6 ft wide gap between the duct and the side of the floor opening.

Keywords: LIFELINE, UNGUARDED FL OPENING, WORK RULES, SAFETY BELT, WALKING ON PLANK, CONSTRUCTION, FALL, FALL PROTECTION, FLOOR OPENING, LOST BALANCE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1438175 Fatality Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.