Inspection Detail
Inspection: 1434710.015 - Rsd - Total Control
Inspection Information - Office: Fresno District Office
Site Address: 
			   Rsd - Total Control
			   2140 E Clubhouse
Fresno, CA 93720
Mailing Address: 
			   5920 E Shields Ave #101, Fresno, CA 93727
Union Status: NonUnion
SIC:
NAICS: 541618/Other Management Consulting Services
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/26/2020
Emphasis:
Case Closed: 03/27/2020
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 1504061 | ||
| Inspection | 1434713 | Yes | 
Investigation Summary
At 9:06 p.m. on September 28, 2019, an employee was working on an air conditioning system and was replacing a capacitor without turning off its circuit breaker. The employee was electrocuted.
Keywords: Air Conditioner, Electrical, Electrocuted, Maintenance
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 1434710.015 | 64 | M | Fatality | Managers and administrators, n.e.c | 