Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Ft. Lauderdale | ||||
---|---|---|---|---|
Nr: 1420535.015 | Report ID: 0418800 | Open Date: 08/02/2019 | ||
Outstanding Construction Design, Inc. | ||||
600 Countryside Dr. Naples, FL 34104 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 238910/Site Preparation Contractors | ||||
Mailing: 7615 Sw River Street, Fort Ogden, FL 34267 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Complete | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 08/02/2019 | |
Close Case: | 11/06/2020 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1483489 |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 118590.015 | Event: 08/01/2019 | Employee Is Killed When Lightning Strikes Golf Course | ||||
At 2:00 p.m. on August 1, 2019, Employee #1, employed by a construction company, was working at the site of a new golf course. He was measuring decorative rock around a lake when lightning struck. Employee #1 was electrocuted. | ||||||
Keywords: struck by, lightning, electrocuted, construction, water | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1420535.015 | Fatality | Other | Construction trades, n.e.c. |