Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Ft. Lauderdale | ||||
|---|---|---|---|---|
| Nr: 1415159.015 | Report ID: 0418800 | Open Date: 07/15/2019 | ||
| Exotic Performance Engineering Inc. | ||||
| 10788 Sw 188th Streetnull Cutler Bay, FL 33157 | Union Status: NonUnion | |||
| SIC: | ||||
| NAICS: 541330/Engineering Services | ||||
| Mailing: 10788 Sw 188th Streetnull, Cutler Bay, FL 33157 | ||||
| Inspection Type: | Fat/Cat | |||
| Scope: | Complete | Advanced Notice: | N | |
| Ownership: | Private | |||
| Safety/Health: | Health | Close Conference: | 07/15/2019 | |
| Close Case: | 03/11/2020 | |||
| Related Activity: | Type | ID | Safety | Health |
| Accident | 1475805 | |||
Case Status: CLOSED |
Violation Summary | ||||||
|---|---|---|---|---|---|---|
| Serious | Willful | Repeat | Other | Unclass | Total | |
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
| Violation Items | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| # | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
| 1. | 01001 | Serious | 19101000 A02 | 01/10/2020 | $0 | $0 | $0 | Z - Issued | |||
Accident Investigation Summary | ||||||
| Summary Nr: 117925.015 | Event: 07/13/2019 | Employee Dies From Overexposure To Carbon Monoxide | ||||
| At 10:00 a.m. on July 13, 2019, Employee #1 was operating a propane powered conc rete floor grinder. There was no ventilation in the area. The carbon monoxide bu ilt up, causing the death of the employee due to lack of oxygen. | ||||||
| Keywords: carbon monoxide, grinder, overexposure, propane, ventilation | ||||||
| Inspection | Degree | Nature | Occupation | |||
|---|---|---|---|---|---|---|
| 1 | 1415159.015 | Fatality | Garage and service station related occupations | |||