Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Ft. Lauderdale | ||||
---|---|---|---|---|
Nr: 1398409.015 | Report ID: 0418800 | Open Date: 05/03/2019 | ||
Jc & A Electrical Contractors, Inc. | ||||
1010 South Federal Hwy Hallandale Beach, FL 33009 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 238210/Electrical Contractors | ||||
Mailing: 1901 Nw 108 Ave, Miami, FL 33172 | ||||
Inspection Type: | Fat/Cat | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 05/03/2019 | |
Emphasis: | L:Fall | Close Case: | 11/01/2019 | |
Related Activity: | Type | ID | Safety | Health |
Accident | 1451594 | Yes |
Case Status: CLOSED |
Accident Investigation Summary | ||||||
Summary Nr: 115962.015 | Event: 05/03/2019 | Employee Is Killed In Fall Down Elevator Shaft | ||||
At 9:30 a.m. on May 3, 2019, Employee #1, employed by an electrical services company, was engaged in electrical work at a new commercial building. He was installing a temporary electrical box on the nineteenth floor and wiring or conduit pipes between the eighteenth and nineteenth floors. Employee #1 fell down an elevator shaft, from the nineteenth floor to the bottom of the shaft on the ninth floor. He was killed in the fall. | ||||||
Keywords: conduit, electrical box, electrician, fall protection, installing, elevator shaft, electrical work, fall, construction | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1398409.015 | Fatality | Other | Electricians |