Inspection Detail
Inspection: 1387647.015 - Harold Brothers Mechanical Contractors, Inc.
Inspection Information - Office: Boston South Area Office
Site Address:
Harold Brothers Mechanical Contractors, Inc.
1577 Falmouth Road (Route 28) Mspca
Centerville, MA 02632
Mailing Address:
44 Woodrock Road, Weymouth, MA 02189
Union Status: NonUnion
SIC:
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/08/2019
Emphasis:
Case Closed: 10/04/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1439027 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $10,606 | $0 | $0 | $6,630 | $0 | $17,236 |
| Current Penalty | $5,303 | $0 | $0 | $2,000 | $0 | $7,303 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100147 C04 I | 08/21/2019 | 10/10/2019 | $5,303 | $5,303 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100147 C07 IV | 08/21/2019 | 10/10/2019 | $0 | $5,303 | $0 | I - Informal Settlement | ||
| 3. | 02001 | Other | 19040039 A01 | 08/21/2019 | 10/10/2019 | $2,000 | $6,630 | $0 | I - Informal Settlement |
Investigation Summary
At 8:30 a.m. on March 7, 2019, Employee #1 was attempting to stop a leak in a hot water central heating system. The attempt to stop the leak exacerbated the leak and the system started spraying out treated, scalding hot water. The employee experienced respiratory distress resulting from a pre-existing condition (Chronic Obstructed Pulmonary Disease) exacerbated by inhalation of propylene glycol aerosols and possible thermal burns from hot water under pressure. The employee was killed.
Keywords: Hot Water, Inhalation, Leak, Respiratory Tract
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1387647.015 | 71 | M | Fatality | Plumber, pipefitter and steamfiter apprentices |
Translate