Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 1364041 - Spindle Top Geophysical Corp

Inspection Information - Office: Houston North

Nr: 1364041Report ID: 0626600Open Date: 11/14/1984

Spindle Top Geophysical Corp
Fm 2712
Crockett, TX 75835
Union Status: NonUnion
SIC: 1382/Oil and Gas Field Exploration Services
Mailing: Po Box 271, Beaumont, TX 77704

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:11/21/1984
Close Case:07/03/1985

Related Activity:TypeIDSafetyHealth
 Accident360549018    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $280 $0 $0 $0 $0 $280
Current Penalty $140 $0 $0 $0 $0 $140
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001A Serious 19260900 H 12/05/1984 12/08/1984 $140 $280 $0 12/17/1984 F - Formal Settlement
  2. 01001B Serious 19260900 O 12/05/1984 12/08/1984 $0 $0 $0 12/17/1984 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 14237226Event: 11/13/1984Electric Shock - Contact With Overhead Line Thru Conductor
A CREW OF EMPLOYEES, CONSISTING OF A SHOOTER, A SHOOTER'S HELPER, AND A TRUCK DRIVER, WERE PERFORMING AN OPERATION CALLED "SHOOTING A HOLE". THIS OPERATION, WHICH IS PERFORMED TO DETERMINE IF OIL OR GAS DRILLING IS FEASIBLE, INVOLVES THE DETONATION OF EXPLOSIVE CHARGES IN A HOLE IN THE GROUND. AT THE ACCIDENT SCENE, A 100-FOOT-DEEP, 4-INCH-DIAMETER HOLE HAD BEEN DRILLED TWO DAYS EARLIER, AND A 20-POUND CHARGE OF TNT HAD BEEN SET WITHIN IT. A SET OF 100-FOOT CAP LEADS (ELECTRICAL CONDUCTORS) HAD BEEN ATTACHED TO THE EXPLOSIVE CHARGE, AND THE SHOOTER ATTACHED THE OTHER END OF THE LEADS TO A "SHOOTER BOX", WHICH ARMS THE CHARGE. THE SHOOTER RADIOED THE TRUCK DRIVER, WHO WAS IN THE RECORDING TRUCK, TO DETONATE THE CHARGE. WHEN DETONATION OCCURRED, THE LEADS FLEW UP OUT OF THE HOLE INTO 7200-VOLT OVERHEAD POWER LINES. THE LEADS CONDUCTED THE CURRENT TO THE SHOOTER, WHO WAS HOLDING THE FIRING BOX, AND HE WAS ELECTROCUTED.
Keywords: explosives, overhead power line, electrical, electrocuted, e gi ic, detonator lead
Inspection Degree Nature Occupation
1 1364041 Fatality Electric Shock Explosives workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.