Inspection Detail
Case Status: CLOSED |
Inspection Information - Office: Ca Monrovia District Office | ||||
---|---|---|---|---|
Nr: 1346117.015 | Report ID: 0950644 | Open Date: 09/13/2018 | ||
Heartland Technology Group | ||||
9817 S. 7th St. Ste. #702 Rancho Cucamonga, CA 91730 | Union Status: NonUnion | |||
SIC: | ||||
NAICS: 423690/Other Electronic Parts and Equipment Merchant Wholesalers | ||||
Mailing: 1700 Stephan St., Little Chute, WI 54140 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | Private | |||
Safety/Health: | Safety | Close Conference: | 12/18/2018 | |
Close Case: | 06/24/2019 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 1379340 |
Case Status: CLOSED |
Violation Summary | ||||||
---|---|---|---|---|---|---|
Serious | Willful | Repeat | Other | Unclass | Total | |
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $18,000 | $0 | $0 | $0 | $0 | $18,000 |
Current Penalty | $18,000 | $0 | $0 | $0 | $0 | $18,000 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
Violation Items | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
1. | 01001 | Serious | 4002(A) | 12/19/2018 | $18,000 | $18,000 | $0 | 01/17/2019 | O - Administrative Law Judge Order |
Accident Investigation Summary | ||||||
Summary Nr: 111039.015 | Event: 09/05/2018 | Employee'S Right Index Fingertip Is Amputated By Hydraulic P | ||||
At 9:00 a.m. on September 5, 2018, Employee #1, employed by a technology products and services company, noticed the width of the paper was incorrect in Press #2. He removed the paper and proceeded to load the correct new roll of paper onto Press #2. Employee #1 placed a core roll behind the new roll of paper so the paper would align with the feed. He hit the lever to raise the roll holder. As Employee #1 was pushing the roll of paper onto the holder, he placed his hand onto the hydraulic piston to get leverage. The hydraulic piston moved up, pinching Employee #1's right index finger between the head and body of the piston. His right index fingertip was amputated. | ||||||
Keywords: piston, roller--mach/part, amputated, pinched, amputation, finger, fingertip, press | ||||||
Inspection | Degree | Nature | Occupation | |||
---|---|---|---|---|---|---|
1 | 1346117.015 | Non Hospitalized injury | Amputation | Pressing machine operators |