Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1318542.015 - Triangle X Ranch

Inspection Information - Office: Wyoming Department Of Workforce Services - Osha Division

 

Inspection Nr: 1318542.015
Report ID: 0855610
Date Opened: 05/10/2018

Site Address:
Triangle X Ranch
7945 Riverview Road
Kinnear, WY 82516

Mailing Address:
2 Triangle X Ranch Road, Moose, WY 83012

Union Status: NonUnion

SIC:

NAICS: 111940/Hay Farming


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/24/2018

Emphasis:

Case Closed: 04/04/2019


Related Activity
Type Activity Nr Safety Health
Accident 1341761
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $38,802 $0 $0 $5,000 $0 $43,802
Current Penalty $16,584 $0 $0 $3,087 $0 $19,671
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 B01 09/28/2018 10/24/2018 $4,146 $6,467 $0 I - Informal Settlement  
2. 01002 Serious 19100332 B02 09/28/2018 10/24/2018 $0 $6,467 $0 I - Informal Settlement  
3. 01003 Serious 19100333 A01 09/28/2018 10/24/2018 $0 $6,467 $0 I - Informal Settlement  
4. 01004 Serious 19100333 B02 III A 09/28/2018 10/24/2018 $4,146 $6,467 $0 I - Informal Settlement  
5. 01005 Serious 19100333 B02 IV B 09/28/2018 10/24/2018 $4,146 $6,467 $0 I - Informal Settlement  
6. 01006 Serious 19100335 A01 I 09/28/2018 10/24/2018 $4,146 $6,467 $0 I - Informal Settlement  
7. 02001 Other 19040039 A01 09/28/2018 10/24/2018 $3,087 $5,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 105955.015
Event: 05/09/2018
Employee contacts 480 volt control box and is electrocuted

At 5:00 p.m. on May 9, 2018, Employee #1 was working on an energized center irrigation pivot. During work, Employee #1 contacted a 480 volt control box that operates a boost pump and was electrocuted.

Keywords: Electric Pump, Electrocuted, Lockout, Pump, Struck Against

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1318542.015 56 M Fatality
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close