Inspection Detail
Inspection: 1305363.015 - Diamond Oilfield Services, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Diamond Oilfield Services, Inc.
E1240 And N2490
Geary, OK 73040
Mailing Address:
4201 S. Radio Road, El Reno, OK 73036
Union Status: NonUnion
SIC:
NAICS: 237120/Oil and Gas Pipeline and Related Structures Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/30/2018
Emphasis:
Case Closed: 08/10/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1323197 | Yes |
Investigation Summary
At 10:00 a.m. on March 29, 2018, Employee #1 through #6, employed by a pipeline services company, were repairing a natural gas cooling unit. The piping on a nearby cooling unit failed, and the pipe flew out and struck the six employees. Employee #1 was most seriously injured; his right lower leg was amputated. Emergency services were called, and the six employees were transported to the hospital. Employee #1 required hospitalization and treatment for the leg amputation. His coworkers were treated and released.
Keywords: Amputation, Construction, Cooling Tower, Falling Object, Flying Object, Leg, Natural Gas, Pipe, Repair, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1305363.015 | 30 | M | Hospitalized injury | Plumbers, pipefitters and steamfitters |