Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: CLOSED
Inspection: 1293087.015 - Progress Rail Service

Inspection Information - Office: Dallas

Nr: 1293087.015Report ID: 0626300Open Date: 02/06/2018

Progress Rail Service
830 East Texas Avenue
Waskom, TX 75692
Union Status: NonUnion
SIC:
NAICS: 336510/Railroad Rolling Stock Manufacturing
Mailing: 830 East Texas Avenue, Waskom, TX 75692

Inspection Type:Referral
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:02/06/2018
Close Case:04/12/2018

Related Activity:TypeIDSafetyHealth
 Referral1305428 Yes  
Case Status: CLOSED

Accident Investigation Summary
Summary Nr: 102862.015Event: 01/30/2018Employee Is Using An Acetylene Torch Burns When It Burst Int
At 10:25 a.m. on January 30, 2018, an employee was cutting up railroad cars for scrap and a small leak developed in the acetylene tank near the oxygen line. The line burst into fire and the employee suffered a burn to his chest. The employee was hospitalized.
Keywords: railroad car, acetylene, burn, fire, chest, acetylene torch
Inspection Degree Nature Occupation
1 1293087.015 Hospitalized injury Burn/Scald(Heat) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.