Powered by GoogleTranslate

Inspection Detail

Inspection: 126793173 - Quikrete Companies

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 126793173
Report ID: 0854910
Date Opened: 09/22/1998

Site Address:
Quikrete Companies
490 West 3300 South
Salt Lake City, UT 84115

Mailing Address:
490 West 3300 South, Salt Lake City, UT 84115

Union Status: NonUnion

SIC:3273

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/03/1998

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/31/1998


Related Activity
Type Activity Nr Safety Health
Accident 362649832
Complaint 77720902 Yes Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 3 8
Current Violations 5 3 8
Initial Penalty $9,750 $0 $0 $975 $0 $10,725
Current Penalty $9,750 $0 $0 $975 $0 $10,725
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 10005 C07 11/23/1998 11/30/1998 $1,950 $1,950 $0 -  
2. 01001B Serious 19100304 E01 IV 11/23/1998 01/12/1999 $0 $0 $0 -  
3. 01001C Serious 19100304 F04 11/23/1998 01/12/1999 $0 $0 $0 -  
4. 01001D Serious 19100305 A01 I 11/23/1998 01/12/1999 $0 $0 $0 -  
5. 01001E Serious 19100305 B02 11/23/1998 01/12/1999 $0 $0 $0 -  
6. 01001F Serious 19100305 G01 III 11/23/1998 01/12/1999 $0 $0 $0 -  
7. 01001G Serious 19100305 G02 II 11/23/1998 01/12/1999 $0 $0 $0 -  
8. 01001H Serious 19100305 G02 III 11/23/1998 01/12/1999 $0 $0 $0 -  
9. 01001I Serious 19100332 B01 11/23/1998 11/30/1998 $0 $0 $0 -  
10. 01001J Serious 19100333 A01 11/23/1998 11/30/1998 $0 $0 $0 -  
11. 01001K Serious 19100335 B01 11/23/1998 11/30/1998 $0 $0 $0 -  
12. 01002A Serious 50002 A01 11/23/1998 11/30/1998 $1,950 $1,950 $0 -  
13. 01002B Serious 19100219 C02 I 11/23/1998 11/30/1998 $0 $0 $0 -  
14. 01002C Serious 19100219 E03 I 11/23/1998 11/30/1998 $0 $0 $0 -  
15. 01002D Serious 19100219 F03 11/23/1998 11/30/1998 $0 $0 $0 -  
16. 01002E Serious 19100253 E05 IV 11/23/1998 11/30/1998 $0 $0 $0 -  
17. 01003A Serious 19100134 B10 11/23/1998 01/12/1999 $1,950 $1,950 $0 -  
18. 01003B Serious 19100134 E04 11/23/1998 01/12/1999 $0 $0 $0 -  
19. 01003C Serious 19100134 E05 11/23/1998 01/12/1999 $0 $0 $0 -  
20. 01003D Serious 19101000 C 11/23/1998 11/30/1998 $0 $0 $0 -  
21. 01003E Serious 19101000 E 11/23/1998 12/11/1998 $0 $0 $0 -  
22. 01004A Serious 19100146 C02 11/23/1998 11/30/1998 $1,950 $1,950 $0 -  
23. 01004B Serious 19100146 D05 I 11/23/1998 11/30/1998 $0 $0 $0 -  
24. 01005A Serious 19100178 F02 11/23/1998 11/30/1998 $1,950 $1,950 $0 -  
25. 01005B Serious 19100178 L 11/23/1998 11/30/1998 $0 $0 $0 -  
26. 02001A Other 10005 D03 11/23/1998 01/12/1999 $325 $325 $0 -  
27. 02001B Other 19100022 A01 11/23/1998 01/12/1999 $0 $0 $0 -  
28. 02001C Other 19100022 A03 11/23/1998 01/12/1999 $0 $0 $0 -  
29. 02001D Other 19100023 C01 11/23/1998 01/12/1999 $0 $0 $0 -  
30. 02001E Other 19100141 B01 VI 11/23/1998 01/12/1999 $0 $0 $0 -  
31. 02002A Other 50002 A05 11/23/1998 01/12/1999 $325 $325 $0 -  
32. 02002B Other 19100212 A03 II 11/23/1998 01/12/1999 $0 $0 $0 -  
33. 02002C Other 19100212 B 11/23/1998 01/12/1999 $0 $0 $0 -  
34. 02002D Other 19100242 B 11/23/1998 01/12/1999 $0 $0 $0 -  
35. 02003A Other 19100095 C01 11/23/1998 01/12/1999 $325 $325 $0 -  
36. 02003B Other 19100095 D01 11/23/1998 01/12/1999 $0 $0 $0 -  
37. 02003C Other 19100095 G01 11/23/1998 01/12/1999 $0 $0 $0 -  
38. 02003D Other 19100095 I02 11/23/1998 01/12/1999 $0 $0 $0 -  
39. 02003E Other 19100095 K01 11/23/1998 01/12/1999 $0 $0 $0 -  
40. 02003F Other 19100095 M01 11/23/1998 01/12/1999 $0 $0 $0 -  
41. 02003G Other 19100095 M02 11/23/1998 01/12/1999 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 171057011
Event: 09/28/1998
BURN - ELECTRICAL FAULT IN SWITCH

An employee was repairing an electrical problem in a plant. He was removing an existing switch that was no longer connected to any machinery. The supply side of the 277-volt switch was still energized. As the employee was using a screwdriver, it contacted the energized side of the switch and the front of the metal enclosure simultaneously, causing an electrical fault. The ensuing electric arc burned the employee on the face and injured his eyes.

Keywords: BURN, ELECTRIC ARC, E GI IV, ELECTRICAL, ELECTRIC SWITCH, INSULATED TOOL, ELECTRICAL WORK, LOCKOUT, ELECTRICAL FAULT, HAND TOOL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126793173 Non Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close