Powered by GoogleTranslate

Inspection Detail

Inspection: 126760909 - Western Rental/Sales

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 126760909
Report ID: 0854910
Date Opened: 06/17/1996

Site Address:
Western Rental/Sales
240 West 9400 South
Sandy, UT 84070

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7353

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/18/1996

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 07/25/1996


Related Activity
Type Activity Nr Safety Health
Accident 361535024
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 9 9
Current Violations 9 9
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100022 A02 06/28/1996 07/02/1996 $0 $0 $0 -  
2. 01002 Other 19100101 B 06/28/1996 07/02/1996 $0 $0 $0 -  
3. 01003 Other 19100132 A 06/28/1996 06/28/1996 $0 $0 $0 -  
4. 01004 Other 19100133 A01 06/28/1996 07/02/1996 $0 $0 $0 -  
5. 01005 Other 19100252 A02 II 06/28/1996 07/02/1996 $0 $0 $0 -  
6. 01006 Other 19100305 G02 II 06/28/1996 07/02/1996 $0 $0 $0 -  
7. 01007 Other 19101200 F05 06/28/1996 07/31/1996 $0 $0 $0 -  
8. 01008 Other 19101200 G08 06/28/1996 07/31/1996 $0 $0 $0 -  
9. 01009 Other 19101200 H01 06/28/1996 07/31/1996 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 171054273
Event: 06/17/1996
Two employees burned during repair of industrial roller

Employees #1 and #2 were using an oxy-acetylene torch to repair a roller when they started a small fire on the roller motor housing. Employee #1 picked up a small fire extinguisher to put out the fire, but his coveralls were stained with grease and oil, and while trying to extinguish the blaze he caught fire himself. Employee #2 went to assist him, but he, too, was wearing coveralls stained with oil and grease, and he caught on fire. The fires on both employees were extinguished, and they were flown by helicopter to the University of Utah Burn Center.

Keywords: BURN, CLOTHING, REPAIR, ACETYLENE TORCH, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, ROLLER--MACH/PART

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126760909 Hospitalized injury Burn/Scald(Heat) Heavy equipment mechanics
2 126760909 Hospitalized injury Burn/Scald(Heat) Heavy equipment mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.