Powered by GoogleTranslate

Inspection Detail

Inspection: 126196328 - Structural Composite Industries

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 126196328
Report ID: 0950644
Date Opened: 11/01/2004

Site Address:
Structural Composite Industries
336 Enterprise Place
Pomona, CA 91768

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3599

NAICS: 332710/Machine Shops


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/05/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/05/2005


Related Activity
Type Activity Nr Safety Health
Accident 362595340
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 1 1
Initial Penalty $36,000 $0 $0 $795 $0 $36,795
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314 G 05/06/2005 05/18/2005 $0 $795 $0 I - Informal Settlement  
2. 02001 Serious 3314 C 05/06/2005 05/18/2005 $0 $18,000 $0 I - Informal Settlement Citation has been deleted.
3. 03001 Serious 4184 A 05/06/2005 05/18/2005 $0 $18,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201799319
Event: 11/11/2004
Employee's Finger Is Amputated in Spin Machine

At approximately 8:00 a.m. on November 11, 2004, Employee #1 was working in the Spin Department of Structural Composite Industries (SCI) and was operating Spin Machine Number 4. He was producing a dome and neck at the ends of a straight walled, cylindrical, aluminum pressure vessel. As part of the spin machine operation, the employee attempted to clean the steel roller by sanding the aluminum shaving build-up off the roller wheel. His fingers became caught in the inbound nip point between the roller wheel and the pressure vessel. He suffered an amputation to the tip of his left index finger and was hospitalized. During the investigation it was discovered that the spin machine operation does not have a specific hazardous energy control procedure. In addition, the spin machine did not have provisions to prevent the operator, or other employee passing by, from reaching into the inbound nip point between the roller wheel and aluminum pressure vessel.

Keywords: AMPUTATED, PRESSURE VESSEL, FINGER, CLEANING, MACHINE OPERATOR, ROLLER--MACH/PART, CAUGHT BETWEEN, NIP POINT, FORMING MACHINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126196328 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.