Powered by GoogleTranslate

Inspection Detail

Inspection: 126162239 - Design Pacific Industries

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 126162239
Report ID: 0950642
Date Opened: 11/24/1998

Site Address:
Design Pacific Industries
1234 E 58th St
Los Angeles, CA 90011

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2511

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/24/1999

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362535221
Accident 362544710
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $10,000 $0 $0 $500 $0 $10,500
Current Penalty $90 $0 $0 $10 $0 $100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 461 A 05/21/1999 06/03/1999 $10 $500 $0 07/01/1999 J - ALJ Decision  
2. 02001 Serious 465 D 05/21/1999 06/03/1999 $45 $5,000 $0 07/01/1999 J - ALJ Decision  
3. 03001 Serious 466 A 05/21/1999 06/03/1999 $45 $5,000 $0 07/01/1999 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201051976
Event: 11/24/1998
Employees injured when pressure vessel explodes

At approximately 8:00 a.m. on November 24, 1998, Employee's #1, 2, and 3 were working in the mill area. They were either near or in the pathway of a pressure vessel which exploded. All three employees were hospitalized. Employee #1 and Employee #3 received strains and sprains and Employee #2 received fractures. The accident resulted from a weakened pressure vessel wall and over pressurization of the vessel. Evidence shows that improper welding and patching had been performed on the pressure vessel, that the pressure gauge was not operating properly, and the safety relief valve did not operate properly. Interviews showed that this pressure vessel had not been properly permitted and maintained, the pressure-indicating gauge was not functioning and unlawful welding and patching had been performed on the pressure vessel.

Keywords: FRACTURE, EXPLOSION, SPRAIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126162239 Hospitalized injury Strain/Sprain Furniture and wood finishers
2 126162239 Hospitalized injury Fracture Furniture and wood finishers
3 126162239 Hospitalized injury Strain/Sprain Furniture and wood finishers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.