Powered by GoogleTranslate

Inspection Detail

Inspection: 126110105 - Chemtrans

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126110105
Report ID: 0950641
Date Opened: 06/01/2001

Site Address:
Chemtrans
14700 Avalon Bl.
Los Angeles, CA 90248

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4212

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/13/2001

Emphasis:

Case Closed: 06/25/2002


Related Activity
Type Activity Nr Safety Health
Accident 362568461
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 2 2 4
Initial Penalty $9,450 $0 $0 $700 $0 $10,150
Current Penalty $1,980 $0 $0 $100 $0 $2,080
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400001 11/13/2001 11/26/2001 $100 $175 $0 03/01/2002 F - Formal Settlement  
2. 01002 Other 3203 A 11/13/2001 11/26/2001 $0 $350 $0 03/01/2002 F - Formal Settlement Citation has been deleted.
3. 01003 Other 3400 C 11/13/2001 11/26/2001 $0 $175 $0 03/01/2002 F - Formal Settlement  
4. 02001 Serious 3209 A 11/13/2001 12/07/2001 $180 $4,725 $0 03/01/2002 F - Formal Settlement  
5. 03001 Serious 3210 C 11/13/2001 11/19/2001 $1,800 $4,725 $0 03/01/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201162708
Event: 05/24/2001
Employee injured cleaning a chemical storage tank

At approximately 8:45 p.m. on May 24, 2001, an employee was injured while steam cleaning a chemical storage tank. A flexible hose connected the spinner nozzle to the source of steam. The spinner nozzle had been running for 35 minutes when the clamp attaching the spinner nozzle to the hose became loose. The spinner nozzle became separated from the hose while the steam was running. This caused the hose to fly uncontrollably, spraying the employee in the face with steam. The employee jumped from the top of the trailer to the ground trying to avoid being sprayed further with steam. The employee sustained a minor cut to the back of the head in the fall as well as a steam burn on his face. The employee did not attach fall protection as required by the employer. The employee was transported to Gardena Memorial Hospital where he was treated and released within 3 hours.

Keywords: BURN, HEAD, STEAM CLEANER, STEAM, LACERATION, FALL, FALL PROTECTION, FACE, MECH MALFUNCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126110105 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close