Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 126105287 - Ahf Ducommun Inc.

Inspection Information - Office: Ca Los Angeles

Nr: 126105287Report ID: 0950641Open Date: 12/18/2000

Ahf Ducommun Inc.
140 E. Gardena Blvd.
Gardena, CA 90247
Union Status: NonUnion
SIC: 3728/Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Mailing: 268 E. Gardena Blvd., Gardena, CA 90247

Inspection Type:Accident
Scope:Partial Advanced Notice:N
Ownership:Private
Safety/Health:Safety Close Conference:03/28/2001
Planning Guide: Safety-Manufacturing Close Case:10/20/2006

Related Activity:TypeIDSafetyHealth
 Accident362570988    

Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $18,000 $0 $0 $750 $0 $18,750
Current Penalty $4,500 $0 $0 $600 $0 $5,100
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 3203 A07 03/29/2001 04/30/2001 $600 $750 $0 08/14/2001 F - Formal Settlement
  2. 02001 Serious 4184 B 03/29/2001 04/23/2001 $4,500 $18,000 $0 08/14/2001 F - Formal Settlement

Accident Investigation Summary
Summary Nr: 201162203Event: 12/05/2000An Employee Amputated His Left Finger
On December 5, 2000, an employee, hired as a general helper, started working in building 14, along with three other employees as directed by the second shift supervisor. With a 15 ton overhead crane, they placed the 8 ft by 15 ft sheet metal in position over the center die. The employees inserted the material's edge into the north (left) and south (right) jaws. The jaws were closed to hold the material in place. The position of the sheet metal did not match the die. The jaws were opened to be realigned. On all the sides the shims were fine except the North-West side. The employee from the north-east position came to the north-west position to assist his co- worker. The material was 0.125 inch short of that jaw section. While his left hand which was placed partially inside the open jaw, gave the operator signal to close the gripper jaws on the north side. As the operator pushed the button, the jaw sections started to close from middle to both ends and closed onto his finger. The operator opened the jaw when he realized the employee finger was inside and pulled his hand out of the danger zone. He was hospitalized for his injuries.
Keywords: amputated, finger, press
Inspection Degree Nature Occupation
1 126105287 Hospitalized injury Amputation Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.