Powered by GoogleTranslate

Inspection Detail

Inspection: 126098268 - Gateway Energy

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126098268
Report ID: 0950641
Date Opened: 11/28/2001

Site Address:
Gateway Energy
11855 La Cienega Blvd
Los Angeles, CA 90045

Mailing Address:
1195 Pomona Road #101, Corona, CA 92882

Union Status: NonUnion

SIC:1731

NAICS:  


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/30/2002

Emphasis: S:Construction (Cship)

Case Closed: 01/15/2004


Related Activity
Type Activity Nr Safety Health
Accident 362569824
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $14,400 $0 $0 $0 $0 $14,400
Current Penalty $0 $0 $0 $400 $0 $400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1632 B 04/29/2002 05/02/2002 $400 $14,400 $0 11/04/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201163326
Event: 11/19/2001
Employee injured in fall through mechanical shaft

On November 19, 2001, Employee #1, of Gateway Energy in Corona, CA, was the supervisor for the electrical installation at a new office building. At the time of accident he was tracing a conduit that was running through the framework overhead by visually following it. As he turned a corner, he noticed another worker inside a duct overhead; this distracted him and he fixed his gaze upward. As a result, Employee #1 failed to notice an 4.5 ft by 6.5 ft open mechanical shaft. He fell 15 ft through the unguarded opening, landing on a concrete surface. He fractured both wrists and shattered his elbow.

Keywords: FRACTURE, UNGUARDED FL OPENING, WORK RULES, CONSTRUCTION, SHAFT, FALL, FLOOR OPENING, UNGUARDED, INATTENTION, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126098268 Hospitalized injury Fracture Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close