Powered by GoogleTranslate

Inspection Detail

Inspection: 126091339 - Spartech Plastics

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 126091339
Report ID: 0950644
Date Opened: 05/22/2003

Site Address:
Spartech Plastics
14233 Gannet St
La Mirada, CA 90638

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3081

NAICS: 326113/Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/20/2003

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/23/2008


Related Activity
Type Activity Nr Safety Health
Accident 362591521
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 4 10
Current Violations 1 6 7
Initial Penalty $31,835 $0 $0 $1,400 $0 $33,235
Current Penalty $12,600 $0 $0 $1,350 $0 $13,950
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314 F 06/18/2003 07/18/2003 $150 $280 $0 W - Empr Withdrew  
2. 01002 Other 3661 C 06/18/2003 07/18/2003 $0 $280 $0 W - Empr Withdrew Citation has been deleted.
3. 01003 Other 4305 B 06/18/2003 07/18/2003 $0 $280 $0 W - Empr Withdrew  
4. 01004 Other 5021 A 06/18/2003 07/18/2003 $0 $560 $0 W - Empr Withdrew Citation has been deleted.
5. 02001 Other 23400017 A 06/18/2003 07/02/2003 $300 $3,375 $0 W - Empr Withdrew  
6. 03001 Other 3210 B 06/18/2003 07/02/2003 $300 $3,375 $0 W - Empr Withdrew  
7. 04001 Other 4002 A 06/18/2003 07/02/2003 $300 $3,375 $0 W - Empr Withdrew  
8. 05001 Other 4184 B 06/18/2003 07/02/2003 $300 $3,375 $0 W - Empr Withdrew  
9. 06001 Serious 3203 A 06/18/2003 07/02/2003 $0 $335 $0 W - Empr Withdrew Citation has been deleted.
10. 07001 Serious 3383 B 06/18/2003 07/02/2003 $12,600 $18,000 $0 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201796935
Event: 05/11/2003
Employee Receives Burns To Arm From Hot Plastic

At approximately 2:30 a.m. on May 11, 2003, Employee #1 and a coworker cleaning the feed pipe for the Line No. 10 4.5 Wellex Extruder. The Line No. 10 had been shutdown for cleaning for about 16 hours prior to the incident. During that time the plastic resin in the feed pipes hardened so it was necessary to heat the feed pipe to the point that the plastic would flow out of the pipe. There were four heaters in the feed pipe, each pipe heater is controlled by a thermocouple that turns the heater on and off and each section has a digital temperature gauge. Early in the cleaning process the feed pipe was disconnected from the feed box adapter and the thermocouple had been removed from the bottom section of the feed pipe. Employee #1 did not notice that the thermocouple had been disconnected when he turned on the heaters to melt the solidified plastic in the pipe. The coworker said while he and Employee #1 were waiting for the plastic to soften they were installing other parts on the Line No. 10 Extruder. About 30 minutes later, the coworker said that Employee #1 was using a pair of pliers to pull out the softened plastic plug at the bottom of the feed pipe, when hot plastic sprayed out of the feed. The coworker was not injured and was approximately 2 ft away and some of the hot plastic landed on his long sleeved shirt and he quickly removed it. The hot plastic splashed on Employee #1, causing second and third degree burns. Employee #1 was not wearing the required personal protective equipment at the time of the incident. The employer had experienced a similar accident a few months ago and developed a procedure, provided training, and required the use of PPE when cleaning the feed pipe. Because the thermocouple had been disconnected, the heater did not shut off and the temperature gauge for that section indicated the room temperature not the pipe temperature. Employee said he checked the temperature gauge for the bottom section of the feed pipe, but did not check the other three feed pipe gauges. The three other temperature gauges would have given a better indication of the temperature in the bottom section of the pipe. Employee #1 stated that he was not wearing PPE, because he was just standing next to the feed pipe when the hot plastic sprayed out of the pipe. Employee #1 was hospitalized and treated for second-degree and third-degree burns to his left forearm and hand.

Keywords: BURN, PIPE PLUG, PPE, HEATER, CLEANING, RUPTURE, ARM, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126091339 Hospitalized injury Burn/Scald(Heat) Supervisors, extractive occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.