Powered by GoogleTranslate

Inspection Detail

Inspection: 126072750 - Pacific Resource Recovery

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 126072750
Report ID: 0950642
Date Opened: 02/28/2000

Site Address:
Pacific Resource Recovery
3150 E Pico Bl
Los Angeles, CA 90023

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:4953

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/23/2000

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362609323
Accident 362609331
Accident 362609349
Accident 362609752
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $31,500 $0 $0 $375 $0 $31,875
Current Penalty $28,875 $0 $0 $0 $0 $28,875
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 03/24/2000 04/10/2000 $0 $375 $0 05/04/2000 F - Formal Settlement  
2. 02001 Serious 3210 C 03/24/2000 04/03/2000 $1,875 $4,500 $0 05/04/2000 F - Formal Settlement  
3. 03001 Serious 5168 B 03/24/2000 04/03/2000 $4,500 $4,500 $0 05/04/2000 J - ALJ Decision  
4. 04001 Serious 5420 A02 03/24/2000 04/03/2000 $22,500 $22,500 $0 05/04/2000 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201053154
Event: 02/28/2000
Employee killed in tanker truck explosion

On February 28, 2000, Employee #1 and a coworker, of Pacific Resource Recovery, were cleaning sludge and residual liquid from a tanker truck after 3,800 gallons of flammable liquid waste had been pumped from it into storage tanks at a hazardous waste treatment facility. They were going to use the procedure developed by the employer: a pressure washer to clear the walls of the tank, then a squeegee to push the remaining material to the back of the tank. They were standing atop the tanker truck trying to loosen the sludge with the pressure washer but there was not enough water pressure. Employee #1 asked the coworker to connect the water hose to another connection on the ground that was adjacent to the tanker truck. While the coworker went to do this, Employee #1 began to clean the tank with a squeegee. He was scraping the bottom of the tank when the material exploded into flames. He sustained multiple traumatic injuries and thermal burns. A fire engine and paramedics arrived on the scene and transferred Employee #1 to Los Angeles County/USC Medical Center, where he was pronounced dead. Subsequent investigation revealed that the employer had failed to ensure that the workers had emptied, flushed, or purged flammable vapors trapped inside the tank truck. The employer also failed to test that the flammable vapors were less than 25 percent of the lower explosive limit before they were allowed to clean the tank, a violation of T8CCR 5420(a)(2). The squeegee being used was constructed with a 1 in. Teflon scraper base and a 9 in. aluminum handle attached with seven iron bolts. The metal bolts could have created a spark if they had contacted the sides of the tank. The pressure washer used for cleaning the tank truck was not grounded and bonded, so any static electric charges generated by water rushing at high speed through the washer could not be dissipated, a violation of T8CCR 5168(b).

Keywords: BURN, TANK TRUCK, STATIC ELECTRICITY, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, CLEANING, EXPLOSION, SPARK, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126072750 Fatality Other Technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close