Powered by GoogleTranslate

Inspection Detail

Inspection: 126064450 - Aaa Refinishing Corp.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 126064450
Report ID: 0950643
Date Opened: 11/16/2001

Site Address:
Aaa Refinishing Corp.
1620 N. San Fernando Rd. #52
Burbank, CA 91501

Mailing Address:
2316 W. Burbank Blvd., Burbank, CA 91506

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/07/2002

Emphasis: S:Construction (Cship)

Case Closed: 11/05/2008


Related Activity
Type Activity Nr Safety Health
Accident 362510208
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 6 8
Current Violations 2 6 8
Initial Penalty $13,950 $0 $0 $960 $0 $14,910
Current Penalty $3,465 $0 $0 $610 $0 $4,075
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 05/08/2002 06/03/2002 $175 $175 $0 05/22/2002 F - Formal Settlement  
2. 01002 Other 1512 B 05/08/2002 06/03/2002 $130 $175 $0 05/22/2002 F - Formal Settlement  
3. 01003 Other 5194 H01 05/08/2002 06/03/2002 $175 $260 $0 05/22/2002 F - Formal Settlement  
4. 01004 Other 5144 C01 05/08/2002 06/03/2002 $130 $175 $0 05/22/2002 F - Formal Settlement  
5. 01005 Other 5144 E01 05/08/2002 06/03/2002 $0 $175 $0 05/22/2002 F - Formal Settlement  
6. 01006 Other 5194 F04 05/08/2002 05/22/2002 $0 $0 $0 05/22/2002 F - Formal Settlement  
7. 02001 Serious 1534 A 05/08/2002 05/16/2002 $315 $3,150 $0 05/22/2002 F - Formal Settlement  
8. 03001 Serious 1534 B 05/03/2002 06/03/2002 $3,150 $10,800 $0 05/22/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201113685
Event: 11/09/2001
Employee burned when vapors ignite

On November 9, 2001, an employee was working in apartment number 52 at 1620 North San Fernando Road in Burbank, California. The employee worked for a company that was hired by the apartment complex to refinish the bathroom. The employee had been assigned by his immediate supervisor to refinish the bathtub, the tub walls, and the vanity. The employee first prepped the areas to be refinished by sanding the tub and applying acid to the areas to be reglazed. He then used a Wagner 2000 Finecoat Low Overspray Finishing System to apply the coat of primer. The primer was Primer Filler Catalyst and Primer Filler Base from European Coatings Inc. mixed together. The employee then applied two coats of the topcoat-D.M.G. Products Inc. White Acrylic Urethane, product code MBW-61/1001. While the employee was performing the spray operations in the bathroom, the bathroom door was closed, the compressor for the spray unit was inside the bathroom behind him and a small window in the bathroom was open to attempt to provide ventilation. As the employee was applying the third coat of the topcoat, he heard a noise from behind him, saw flames, and his clothing caught fire. He attempted to exit the bathroom, but the door was closed. He pushed on the door several times before breaking the door. He went down to his work truck and called emergency medical services for assistance but stated that the number was busy. He hung up the phone and contacted the employer's office, who contacted his immediate supervisor, who then contacted emergency medical services. The employee was transported to Sherman Oaks Burn Center were he was hospitalized with first, second and third-degree burns on his arms, hands, and back. The accident was caused by the ignition of flammable vapors that were present in the work area.

Keywords: BURN, VAPOR, VENTILATION, FLAMMABLE VAPORS, FIRE, CONSTRUCTION, ARM, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126064450 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close