Powered by GoogleTranslate

Inspection Detail

Inspection: 126014000 - San Diego City Water Utilities Dept

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 126014000
Report ID: 0950632
Date Opened: 09/26/1995

Site Address:
San Diego City Water Utilities Dept
9150 Topaz Way
San Diego, CA 92123

Mailing Address:
, , 00000

Union Status: Union

SIC:4952

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Safety

Close Conference: 11/15/1995

Emphasis:

Case Closed: 11/19/1996


Related Activity
Type Activity Nr Safety Health
Accident 362250169
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 2
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3328 G 11/08/1995 11/19/1996 $0 $0 $0 11/29/1995 J - ALJ Decision Citation has been deleted.
2. 02001 Serious 5157 G01 C 11/08/1995 12/11/1995 $0 $0 $0 11/29/1995 J - ALJ Decision Citation has been deleted.
3. 03001 Serious 5157 C03 11/08/1995 12/11/1995 $0 $0 $0 11/29/1995 J - ALJ Decision  
4. 04001 Serious 5157 C05 B5B 11/08/1995 12/11/1995 $0 $0 $0 11/29/1995 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170383202
Event: 04/28/1995
Employee overcome by sewer gas during blowout

At approximately 10:00 a.m. on April 28, 1995, Employee #1 entered a 4 1/2 ft deep sewer manhole containing an air release (AR) valve. The valve appeared loose, and while he inspected and scraped rust off a 3/4 in. pipe thread plug installed on the valve, the plug blew out. Sewer gas escaped from the plug hole. Employee #1 was overcome and tried to exit the manhole, but could only get halfway out. A coworker, who was providing traffic control, removed Employee #1 from the manhole, then contacted the company's communication dispatch center and requested emergency assistance. The fire department and paramedics arrived and treated Employee #1, then transported him to a nearby hospital. Employee #1 was treated and released at about 4:10 p.m. the same day.

Keywords: SEWER, CONFINED SPACE, WORK RULES, GAS, VALVE, TOXIC FUMES, MANHOLE, OVEREXPOSURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126014000 Non Hospitalized injury Other Engineering technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.