Inspection Detail
Inspection: 125959098 - Bredero Price Company
Inspection Information - Office: San Bernardino District Office
Site Address:
Bredero Price Company
14000 San Bernardino Avenue Sw Gate #6
Fontana, CA 92335
Mailing Address:
Post Office Box 1317, Fontana, CA 92334
Union Status: NonUnion
SIC:3316
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/17/1996
Emphasis:
Case Closed: 07/02/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362034530 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $0 | $0 | $0 | $1,000 | $0 | $1,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3329 D | 08/05/1996 | 08/08/1996 | $1,000 | $5,000 | $0 | 09/10/1996 | J - ALJ Decision |
Investigation Summary
At approximately 11:00 p.m. on February 18, 1996, Employee #1 and a coworker were attempting to install a blank in a gas line to a processing furnace in the company's galvanizing department. As they removed the bolts holding the section of pipe in place, they felt the gas rushing past their faces. The gas traveled upward to the pilot lights in the furnace, where it was ignited and caused a flashback. Employee #1 sustained second-degree burns to his neck and face, and first-degree burns to his arms. The coworker was not injured.
Keywords: BURN, FURNACE, PILOT LIGHT, FLAMMABLE VAPORS, WORK RULES, FIRE, GAS, FLASHBACK, NECK, FACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 125959098 | Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations |