Powered by GoogleTranslate

Inspection Detail

Inspection: 125945337 - Air Industries Company

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 125945337
Report ID: 0950635
Date Opened: 12/29/2004

Site Address:
Air Industries Company
12570 Knott St
Garden Grove, CA 92841

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3452

NAICS: 332722/ Bolt, Nut, Screw, Rivet, and Washer Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/27/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362467078
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $18,000 $0 $0 $5,375 $0 $23,375
Current Penalty $18,000 $0 $0 $5,375 $0 $23,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/02/2005 02/07/2005 $5,000 $5,000 $0 09/28/2005 W - Empr Withdrew  
2. 01002 Other 14300007 B03 02/02/2005 03/02/2005 $375 $375 $0 09/28/2005 W - Empr Withdrew  
3. 02001 Serious 4070 A 02/02/2005 02/07/2005 $18,000 $18,000 $0 09/28/2005 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201036563
Event: 12/08/2004
Employee Amputates Finger in Driving Belt

On December 8, 2004, Employee #1 was operating a Traub, housing machine in a facility that specializes in manufacturing aerospace fasteners. This machine performs operations to include: making points, drilling, and shaving. On the bottom tray of the machine, oil accumulates and is drained off occasionally by a portable small pumping unit, which includes a pump and a motor. The height of the pumping unit is approximately 1.5 feet and the unit can be moved on the floor through roller wheels that are mounted to it. The motor of the unit drives the pump by a V-belt drive. The drive motor pulley measures 4.5 inches in diameter, and the driven pump pulley is of 3.75 inches in diameter. The center distance between the two pulleys is 8.5 inches and the belt is 0.5-inches wide. The pulleys move in a clockwise direction. There is no manufacture's name or model number on the unit. As Employee #1 attempted to vacuum oil from the Traub machine bed, using a portable vacuum, a rag that he had in his hand fell. He knelt down to pick up the rag, and it got caught by the V-belt pulley, which in turn pulled Employee #1's hand into the pulley. His left index finger was amputated at the point between the belt and the pulley. Employee #1 was initially treated by the facilities clinic and then was transferred to East Gate Medical Center, where he was hospitalized and treated for his injury.

Keywords: AMPUTATED, FINGER, GUARD, MACHINE OPERATOR, WORK STATION, CAUGHT BETWEEN, PULLEY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125945337 Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.