Powered by GoogleTranslate

Inspection Detail

Inspection: 125908731 - Coffman Specialties Inc

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 125908731
Report ID: 0950631
Date Opened: 09/30/1997

Site Address:
Coffman Specialties Inc
Hwy 91 & Hwy 71
Corona, CA 91720

Mailing Address:
4375 Jutland Dr Ste 260, San Diego, CA 92117

Union Status: NonUnion

SIC:1611

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/01/1997

Emphasis:

Case Closed: 07/14/1999


Related Activity
Type Activity Nr Safety Health
Accident 362041576
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $3,500 $0 $0 $300 $0 $3,800
Current Penalty $3,500 $0 $0 $300 $0 $3,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1698 C 10/31/1997 11/05/1997 $300 $300 $0 -  
2. 02001 Serious 2946 A 10/31/1997 11/05/1997 $3,500 $3,500 $0 12/15/1997 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170167910
Event: 09/17/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL POLE

A concrete finisher was using a float with a 10-meter-long aluminum handle to finish concrete. The handle contacted an overhead power line. The employee received an electric shock and burns to his hands and right thigh. He was hospitalized for his injuries.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, METAL POLE, CONCRETE FLOAT, E C, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125908731 Hospitalized injury Electric Shock Concrete and terrazzo finishers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close