Inspection Detail
Inspection: 125879155 - Smart Systems Technologies Inc.
Inspection Information - Office: San Diego District Office
Site Address:
Smart Systems Technologies Inc.
165 S. Las Posas
San Marcos, CA 92069
Mailing Address:
9 Goodyear, Irvine, CA 92618
Union Status: NonUnion
SIC:1731
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/19/2006
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/30/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362411365 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $6,750 | $0 | $0 | $1,500 | $0 | $8,250 |
| Current Penalty | $0 | $0 | $0 | $200 | $0 | $200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1509 A | 12/19/2006 | 01/21/2007 | $100 | $750 | $0 | 01/22/2007 | J - ALJ Decision | |
| 2. | 01002 | Other | 1509 B | 12/19/2006 | 01/21/2007 | $100 | $750 | $0 | 01/22/2007 | J - ALJ Decision | |
| 3. | 02001 | Serious | 3646 L | 12/19/2006 | 01/21/2007 | $0 | $6,750 | $0 | 01/22/2007 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
An electrician was working from a rented Genie scissor lift (Model No. GS-2632) during the construction of a department store. He was working approximately 4.3 meters above the ground, pulling fire alarm system wiring through a nearby wall-mounted box. The wiring originated across the room. A supervisor in another elevated Genie scissor lift was feeding the wiring to the electrician. When the wiring stuck, the electrician stood and moved toward the front of the scissor lift to get close to the box. He fell off the platform, landing on the ground. The electrician died of injuries sustained in the fall. He had not received training on the safe use of elevated platforms before using the scissor lift, and he was not wearing any personal fall protection equipment.
Keywords: CONSTRUCTION, FALL, FALL PROTECTION, ELEVATED WORK PLAT, UNTRAINED, AERIAL LIFT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125879155 | Fatality | Other | Electricians |