Powered by GoogleTranslate

Inspection Detail

Inspection: 125776286 - Ito Packing Co Inc

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 125776286
Report ID: 0950625
Date Opened: 01/30/1997

Site Address:
Ito Packing Co Inc
707 W South Avenue
Reedley, CA 93654

Mailing Address:
P.O. Box 707, Reedley, CA 93654

Union Status: NonUnion

SIC:0723

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/25/1997

Emphasis:

Case Closed: 09/24/1997


Related Activity
Type Activity Nr Safety Health
Accident 361691694
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $685 $0 $0 $0 $0 $685
Current Penalty $685 $0 $0 $0 $0 $685
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203 A07 03/27/1997 04/29/1997 $625 $625 $0 -  
2. 02001 Serious 5155 E01 03/27/1997 04/29/1997 $60 $60 $0 -  

Investigation Summary

Investigation Nr: 201080173
Event: 12/04/1996
Two employees suffer carbon monoxide poisoning

On December 4, 1996, Employees #1 and #2 were consolidating fruit in the refrigerated storage area at a fruit packing facility. It was a large packing house with a year around crew, where fruit was sorted, stored, and packed according to size and quality, and then shipped. At the time of the incident, Employees #1 and #2 were being supervised on an in-and-out basis. Other workers had been using propane-powered forklifts earlier that morning. One of the forklifts, #125, reportedly was not equipped with a catalytic converter and had been emitting nauseous exhaust fumes. Employees #1 and #2 became ill and were diagnosed as suffering from carbon monoxide poisoning by the treating physician. Industrial health care reported the carboxyhemoglobins for both Employees #1 and #2 to be over 32. Direct reading equipment showed elevated levels of carbon monoxide, in excess of 200 ppm, in sheds #1 and #2, which were packing and sorting areas. An effective exhaust ventilation system was available for use in these rooms but was not turned on to conserve energy. Following the incident, one of the forklift units was removed from indoor use. The employer also said it would replace the propane forklifts with electric ones for use indoors whenever possible, and it agreed to keep the ventilation system on in these areas whenever workers were present. The employer was cited for a violation of T8CCR 3203(a)(7), serious, because employees had not been trained about the hazards and signs associated with carbon monoxide exposure; and a violation of T8CCR 5155(e)(1), serious, because the employer should have been aware of the potential for carbon monoxide in areas where propane-powered forklifts were used indoors, and monitored these areas accordingly.

Keywords: VENTILATION, WORK RULES, INHALATION, INDUSTRIAL TRUCK, EXHAUST FUMES, CARBOXYHEMOGLOBIN, CHEMICAL VAPOR, POISONING, OVEREXPOSURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125776286 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 125776286 Hospitalized injury Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.