Powered by GoogleTranslate

Inspection Detail

Inspection: 125775742 - Visalia Unified School District

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 125775742
Report ID: 0950625
Date Opened: 01/10/1998

Site Address:
Visalia Unified School District
801 N Mooney
Visalia, CA 93291

Mailing Address:
5000 W Cypress, Visalia, CA 93277

Union Status: Union

SIC:8299

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Health

Close Conference: 01/10/1998

Emphasis:

Case Closed: 07/02/1998


Related Activity
Type Activity Nr Safety Health
Accident 362283384
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 25400002 B 07/06/1998 07/09/1998 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201082096
Event: 01/09/1998
Two employees seriously burned in paint booth explosion

Two employees were seriously burned in a flash fire that occurred while they were spray painting in a booth at a maintenance facility. There was an explosion, and the facility caught on fire. The employees were able to escape, but the building and the booth was destroyed. The fire department investigation determined that the fire was caused by the ignition of flammable vapors by an undetermined ignition source. Later, it was discovered that there was a gas-fired heater in the booth and the associated electrical wiring, including the thermostat, did not comply with requirements for a Class 1, Division 1, hazardous location. Employee interviews indicated that the heater had been in use, and one employee believed he heard the unit heater come on just before the explosion. The employees were treated at a hospital for first- and second-degree burns.

Keywords: BURN, E GI V, ELECTRICAL, FLAMMABLE VAPORS, SPRAY PAINTING, EXPLOSION, EQUIPMENT APPROVAL, PAINT BOOTH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125775742 Hospitalized injury Burn/Scald(Heat) Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close