Inspection Detail
Inspection: 125730598 - Tehachapi Recycling Inc
Inspection Information - Office: Fresno District Office
Site Address:
Tehachapi Recycling Inc
416 N Dennison Rd
Tehachapi, CA 93561
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5093
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/19/2002
Emphasis:
Case Closed: 03/13/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362096042 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $15,400 | $0 | $0 | $275 | $0 | $15,675 |
| Current Penalty | $0 | $0 | $0 | $550 | $0 | $550 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 B02 | 03/01/2002 | 03/15/2002 | $275 | $275 | $0 | - | ||
| 2. | 02001 | Other | 4353 H | 03/01/2002 | 03/06/2002 | $275 | $15,400 | $0 | 05/15/2002 | J - ALJ Decision |
Investigation Summary
At approximately 7:45 a.m. on August 30, 2001, Employee #1 was using a hydraulic press to smash containers when an explosion occurred in the enclosed area of the press causing the steel door of the press to strike Employee #1 in the left hand. Employee #1 was taken to the hospital and treated for a fractured left hand.
Keywords: FRACTURE, STEEL, EXPLOSION, AUGER, STRUCK BY, HYDRAULIC PRESS, DOOR, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125730598 | Hospitalized injury | Fracture | Occupation not reported |