Powered by GoogleTranslate

Inspection Detail

Inspection: 125717504 - Setzer Forest Products Inc

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 125717504
Report ID: 0950621
Date Opened: 03/02/2004

Site Address:
Setzer Forest Products Inc
1980 Kusel Rd
Oroville, CA 95966

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2431

NAICS: 321918/Other Millwork (including Flooring)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/02/2004

Emphasis: S:Targeted Compl & Consult

Case Closed: 05/03/2007


Related Activity
Type Activity Nr Safety Health
Accident 362343832
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $0 $0 $0 $600 $0 $600
Current Penalty $0 $0 $0 $300 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3942 A 04/15/2004 05/18/2004 $300 $300 $0 08/24/2004 W - Empr Withdrew  
2. 01002 Other 4185 04/15/2004 05/18/2004 $300 $300 $0 08/24/2004 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 201174794
Event: 12/11/2003
Employee's finger caught in machine

At about 10:30 p.m. on December 11, 2003, Employee #1 was working as a resaw operator for a molding mill operated by Setzer Forest Products, Inc. He was resawing stock lumber in a small double headed band resaw. Employee #1 was cutting the boards in half to make door frames. While cutting, the chain that drives the feed rolls fell off. He went through the lockout procedure and shut the machine down. Employee #1 removed the guards and replaced the chain at the drive motor, and then went around to replace the chain at the feed rolls. When he reached into the area of the chain and sprockets, his finger contacted the band saw blade that had not completely stopped. He didn't recognize the movement of the saw blade. Employee #1 was taken to Oroville Hospital where he was treated for an amputated left index finger and released.

Keywords: AMPUTATED, FINGER, WORK STATION, SAW, BLADE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125717504 Non Hospitalized injury Amputation Sawing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.