Inspection Detail
Inspection: 125524769 - Bart
|
Inspection Information - Office: Ca Oakland | ||||
Nr: 125524769 | Report ID: 0950614 | Open Date: 10/18/2002 | ||
Bart | ||||
28601 Dixon St Hayward, CA 94544 | Union Status: Union | |||
SIC: 4011/Railroads, Line-Haul Operating | ||||
Mailing: 800 Madison St, Oakland, CA 94604 | ||||
Inspection Type: | Accident | |||
Scope: | Partial | Advanced Notice: | N | |
Ownership: | LocalGovt | |||
Safety/Health: | Health | Close Conference: | 11/01/2002 | |
Close Case: | 06/21/2006 | |||
Related Activity: | Type | ID | Safety | Health |
Accident | 361489388 |
Serious | Willful | Repeat | Other | Unclass | Total | |
---|---|---|---|---|---|---|
Initial Violations | 1 | 4 | 5 | |||
Current Violations | 1 | 4 | 5 | |||
Initial Penalty | $2,700 | $0 | $0 | $900 | $0 | $3,600 |
Current Penalty | $2,700 | $0 | $0 | $900 | $0 | $3,600 |
FTA Amount | $0 | $0 | $0 | $0 | $0 | $0 |
# | ID | Type | Standard | Issuance | Abate | Curr$ | Init$ | Fta$ | Contest | LastEvent | |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A02 | 11/08/2002 | 12/11/2002 | $225 | $225 | $0 | - | ||
2. | 01002 | Other | 3318 | 11/08/2002 | 11/14/2002 | $150 | $150 | $0 | - | ||
3. | 01003 | Other | 5144 C02 B | 11/08/2002 | 12/11/2002 | $225 | $225 | $0 | - | ||
4. | 01004 | Other | 5144 D01 C | 11/08/2002 | 12/11/2002 | $300 | $300 | $0 | - | ||
5. | 02001 | Serious | 5194 H01 | 11/08/2002 | 12/11/2002 | $2,700 | $2,700 | $0 | - |
Accident Investigation Summary | ||||||
---|---|---|---|---|---|---|
Summary Nr: 201503190 | Event: 10/17/2002 | Employee Overcome By Solvent Vapors | ||||
On October 17, 2002, Employee #1 was repairing an escalator at the South Hayward BART station. While in the bottom pit (approximately 64-in. by 81-in. by 46-in.-deep) cleaning the track transition area using Next Safety Solvent (80-100 trichloroethylene), he lost consciousness. The solvent was 4.5 times heavier than air. His symptoms indicated an exposure to a very high concentration (probably 1000 ppm), however, Employee #1 was treated and released from the hospital. | ||||||
Keywords: unconsciousness, repair, vapor, pit, escalator, fainted | ||||||
Inspection | Degree | Nature | Occupation | |||
1 | 125524769 | Non Hospitalized injury | Other | Occupation not reported |