Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail



Violation Summary
Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $2,700 $0 $0 $900 $0 $3,600
Current Penalty $2,700 $0 $0 $900 $0 $3,600
FTA Amount $0 $0 $0 $0 $0 $0

Violation Items
# ID Type Standard Issuance Abate Curr$ Init$ Fta$ Contest LastEvent
  1. 01001 Other 3203 A02 11/08/2002 12/11/2002 $225 $225 $0 -
  2. 01002 Other 3318 11/08/2002 11/14/2002 $150 $150 $0 -
  3. 01003 Other 5144 C02 B 11/08/2002 12/11/2002 $225 $225 $0 -
  4. 01004 Other 5144 D01 C 11/08/2002 12/11/2002 $300 $300 $0 -
  5. 02001 Serious 5194 H01 11/08/2002 12/11/2002 $2,700 $2,700 $0 -

Accident Investigation Summary
Summary Nr: 201503190 Event: 10/17/2002Employee Overcome By Solvent Vapors
On October 17, 2002, Employee #1 was repairing an escalator at the South Hayward BART station. While in the bottom pit (approximately 64-in. by 81-in. by 46-in.-deep) cleaning the track transition area using Next Safety Solvent (80-100 trichloroethylene), he lost consciousness. The solvent was 4.5 times heavier than air. His symptoms indicated an exposure to a very high concentration (probably 1000 ppm), however, Employee #1 was treated and released from the hospital.
Keywords: unconsciousness, repair, vapor, pit, escalator, fainted
Inspection Degree Nature Occupation
1 125524769 Non Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.