Powered by GoogleTranslate

Inspection Detail

Inspection: 125450429 - Michael R. Lowe

Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114

 

Inspection Nr: 125450429
Report ID: 0355114
Date Opened: 08/11/1994

Site Address:
Michael R. Lowe
835 Locust St.
Herndon, VA 22070

Mailing Address:
4733 Falcon St., Rockville, MD 20853

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Unprog Rel

Scope: No Insp/Other

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/02/1994

Emphasis: L:Ohpwrlne

Case Closed: 01/11/1995


Related Activity
Type Activity Nr Safety Health
Accident 362310013

Investigation Summary

Investigation Nr: 900126
Event: 08/11/1994
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LADDER

A painting contractor (the sole owner of the business) picked up an aluminum ladder and carried it into an overhead power line. He was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, PAINTER, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125450429 Fatality Electric Shock Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close