Powered by GoogleTranslate

Inspection Detail

Inspection: 125290510 - Chatham Manufacturing, A Div Of Cmi Industries, In

Inspection Information - Office: Nc Department Of Labor - Winston-Salem

 

Inspection Nr: 125290510
Report ID: 0453720
Date Opened: 01/31/1995

Site Address:
Chatham Manufacturing, A Div Of Cmi Industries, In
304 E. Main St.
Elkin, NC 28621

Mailing Address:
P.O. Box 620, Elkin, NC 28621

Union Status: NonUnion

SIC:2221

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/21/1995

Emphasis:

Case Closed: 05/11/1995


Related Activity
Type Activity Nr Safety Health
Accident 360494074
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19040002 A02 05/01/1995 07/03/1995 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170121503
Event: 01/26/1995
Four employees suffer possible diesel overexposure

Employees #1 and #3 were weavers; Employee #2 was an inspector/assistant supervisor; and Employee #4 was a startup technician. At approximately 7:00 a.m. on January 26, 1995, Employees #1 through #4 began to suffer from headaches, nausea, and dizziness after smelling odors. Employee #1 vomited and Employee #2 lost consciousness. A diesel-fueled Bonnie Scot boiler may have been the source of the odor. The one story building, which had a ceiling of varying heights (approximately 12 to 22 ft) was heated by the boiler. Employees #1 through #4, who were involved in the accident, did not work with the boiler. The maintenance person who came to service the boiler said that the boiler could "puff" when air currents outside the exhaust stack caused pressure changes in the boiler. He also stated that there was soot on the outside of the boiler's rear gasket on that day. The gasket was replaced.

Keywords: UNCONSCIOUSNESS, GASKET, HEADACHE, BOILER, NAUSEA, AIR CONTAMINATION, DIZZINESS, TOXIC FUMES, OVEREXPOSURE, VOMIT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125290510 Non Hospitalized injury Other Knitting, looping, taping & weaving mach.operators
2 125290510 Non Hospitalized injury Other Knitting, looping, taping & weaving mach.operators
3 125290510 Hospitalized injury Other Knitting, looping, taping & weaving mach.operators
4 125290510 Non Hospitalized injury Other Knitting, looping, taping & weaving mach.operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.