Powered by GoogleTranslate

Inspection Detail

Inspection: 124773052 - Matsushita Electronic Materials Inc

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 124773052
Report ID: 1054191
Date Opened: 11/24/1993

Site Address:
Matsushita Electronic Materials Inc
4114 Heather St
Forest Grove, OR 97116

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/01/1994

Emphasis:

Case Closed: 04/09/1997


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 8
Current Violations 5 5
Initial Penalty $7,350 $0 $0 $0 $0 $7,350
Current Penalty $6,250 $0 $0 $0 $0 $6,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 04/28/1994 05/26/1994 $1,250 $1,250 $0 05/16/1994 L - State Settlement  
2. 01002A Serious 7136002001 04/28/1994 12/13/1993 $1,250 $1,250 $0 05/16/1994 L - State Settlement  
3. 01002B Serious 7136002003 04/28/1994 12/13/1993 $0 $0 $0 05/16/1994 L - State Settlement  
4. 01003A Serious 19100119 I02 II 04/28/1994 11/01/1994 $0 $500 $0 05/16/1994 L - State Settlement Citation has been deleted.
5. 01003B Serious 19100119 I02 III 04/28/1994 11/01/1994 $0 $0 $0 05/16/1994 L - State Settlement Citation has been deleted.
6. 01003C Serious 19100119 I02 IV 04/28/1994 11/01/1994 $0 $0 $0 05/16/1994 L - State Settlement Citation has been deleted.
7. 01004A Serious 19100133 A01 04/28/1994 05/02/1994 $1,250 $1,250 $0 05/16/1994 L - State Settlement  
8. 01004B Serious 702012701 04/28/1994 05/02/1994 $0 $0 $0 05/16/1994 L - State Settlement  
9. 01004C Serious 702013701 D 04/28/1994 05/02/1994 $0 $0 $0 05/16/1994 L - State Settlement  
10. 01004D Serious 702013702 A 04/28/1994 05/02/1994 $0 $0 $0 05/16/1994 L - State Settlement  
11. 01005A Serious 19101200 H02 II 04/28/1994 05/26/1994 $1,250 $1,250 $0 05/16/1994 L - State Settlement  
12. 01005B Serious 19100119 J03 04/28/1994 05/26/1994 $0 $0 $0 05/16/1994 L - State Settlement  
13. 01005C Serious 19100119 L03 04/28/1994 05/26/1994 $0 $0 $0 05/16/1994 L - State Settlement  
14. 01005D Serious 19100119 C01 04/28/1994 05/26/1994 $0 $0 $0 -  
15. 01006 Serious 19100119 L01 04/28/1994 05/02/1994 $0 $300 $0 05/16/1994 L - State Settlement Citation has been deleted.
16. 01007 Serious 740003001 04/28/1994 05/26/1994 $1,250 $1,250 $0 05/16/1994 L - State Settlement  
17. 01008 Serious 19100119 C01 04/28/1994 05/26/1994 $0 $300 $0 05/16/1994 L - State Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 788703
Event: 11/24/1993
Two employees burned with hot oil

Employees #1, the project engineer, and #2, a maintenance technician, were removing a drain plug on an inline filter (strainer) on a hot oil pump system. Valves were closed but not locked out and the pump was shut off. The oil was under pressure (30 to 40 psig) and at 450 degrees F. The plug was being slowly backed out over several minutes. Employees #1 and #2 reported that the plug suddenly popped out and hot oil was emitted, spraying Employee #1 primarily and, Employee #1 to a lesser extent. Employee #2 was able to run out of the area and call coworkers to help. The Forest Grove Fire Department was called and responded. Employees #1 and #2 were transported to Emmanuel Hospital. Employee #2 chose to be treated and released; Employee #1, who was more seriously burned, was admitted and treated in the burn unit. Given the amount of oil that sprayed out of the filter, it appears that at least one of the isolation valves was not completely closed. This incident occurred in an area that had the potential for a flammable atmosphere had the system been in production mode. Employee #1 was an employee of a foreign employer which was a parent company to the employer.

Keywords: BURN, MAINTENANCE, OPEN VALVE, FLAMMABLE LIQUID, DRAIN PLUG, WORK RULES, LOCKOUT, VALVE, ACCIDENTAL DISCHARGE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 124773052 Hospitalized injury Burn/Scald(Heat) Industrial engineers
2 124773052 Non Hospitalized injury Burn/Scald(Heat) Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.